Literature DB >> 12209788

Determination of oxygen gradients in engineered tissue using a fluorescent sensor.

Karin Kellner1, Gregor Liebsch, Ingo Klimant, Otto S Wolfbeis, Torsten Blunk, Michaela B Schulz, Achim Göpferich.   

Abstract

Nutrient and oxygen supply of cells are crucial to tissue engineering in general. If a sufficient supply cannot be maintained, the development of the tissue will slow down or even fail completely. Previous studies on oxygen supply have focused on measurement of oxygen partial pressures (pO(2)) in culture media or described the use of invasive techniques with spatially limited resolution. The experimental setup described here allows for continuous, noninvasive, high-resolution pO(2) measurements over the cross-section of cultivated tissues. Applying a recently developed technique for time-resolved pO(2) sensing using optical sensor foils, containing luminescent O(2)-sensitive indicator dyes, we were able to monitor and analyze gradients in the oxygen supply in a tissue over a 3-week culture period. Cylindrical tissue samples were immobilized on top of the sensors. By measuring the luminescence decay time, two-dimensional pO(2) distributions across the tissue section in contact with the foil surface were determined. We applied this technique to cartilage explants and to tissue-engineered cartilage. For both tissue types, changes were detected in monotonously decreasing gradients of pO(2) from the surface with high pO(2) to minimum pO(2) values in the center of the samples. Nearly anoxic conditions were observed in tissue constructs ( approximately 0 Torr) but not in excised cartilage discs ( approximately 20 Torr) after 1 day. Furthermore, the oxygen supply seemed to strongly depend on cell density and cell function. Additionally, histological analysis revealed a maximum depth of approximately 1.3 mm of regular cartilage development in constructs grown under the applied culture conditions. Correlating analytical and histological analysis with the oxygen distributions, we found that pO(2) values below 11 Torr might impair proper tissue development in the center. The results illustrate that the method developed is an ideal one to precisely assess the oxygen demand of cartilage cultures. Copyright 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 80: 73-83, 2002.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12209788     DOI: 10.1002/bit.10352

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  43 in total

1.  Time-resolved fluorescent imaging of glucose.

Authors:  Michael Schäferling; Meng Wu; Otto S Wolfbeis
Journal:  J Fluoresc       Date:  2004-09       Impact factor: 2.217

Review 2.  Vascularization strategies for tissue engineering.

Authors:  Michael Lovett; Kyongbum Lee; Aurelie Edwards; David L Kaplan
Journal:  Tissue Eng Part B Rev       Date:  2009-09       Impact factor: 6.389

3.  Computational modeling of adherent cell growth in a hollow-fiber membrane bioreactor for large-scale 3-D bone tissue engineering.

Authors:  Davod Mohebbi-Kalhori; Amin Behzadmehr; Charles J Doillon; Afra Hadjizadeh
Journal:  J Artif Organs       Date:  2012-05-19       Impact factor: 1.731

Review 4.  Strategies for improving the physiological relevance of human engineered tissues.

Authors:  Rosalyn D Abbott; David L Kaplan
Journal:  Trends Biotechnol       Date:  2015-04-30       Impact factor: 19.536

5.  Dispersible oxygen microsensors map oxygen gradients in three-dimensional cell cultures.

Authors:  Sasha Cai Lesher-Pérez; Ge-Ah Kim; Chuan-Hsien Kuo; Brendan M Leung; Sanda Mong; Taisuke Kojima; Christopher Moraes; M D Thouless; Gary D Luker; Shuichi Takayama
Journal:  Biomater Sci       Date:  2017-09-26       Impact factor: 6.843

6.  Indicators for optical oxygen sensors.

Authors:  Michela Quaranta; Sergey M Borisov; Ingo Klimant
Journal:  Bioanal Rev       Date:  2012-11-24

7.  Nonsteady state oxygen transport in engineered tissue: implications for design.

Authors:  Seema M Ehsan; Steven C George
Journal:  Tissue Eng Part A       Date:  2013-03-13       Impact factor: 3.845

Review 8.  Tumor-on-a-chip for integrating a 3D tumor microenvironment: chemical and mechanical factors.

Authors:  L Wan; C A Neumann; P R LeDuc
Journal:  Lab Chip       Date:  2020-03-03       Impact factor: 6.799

9.  Pericellular oxygen monitoring with integrated sensor chips for reproducible cell culture experiments.

Authors:  J Kieninger; K Aravindalochanan; J A Sandvik; E O Pettersen; G A Urban
Journal:  Cell Prolif       Date:  2014-01-25       Impact factor: 6.831

10.  The effect of hypoxia on the chondrogenic differentiation of co-cultured articular chondrocytes and mesenchymal stem cells in scaffolds.

Authors:  Ville V Meretoja; Rebecca L Dahlin; Sarah Wright; F Kurtis Kasper; Antonios G Mikos
Journal:  Biomaterials       Date:  2013-03-13       Impact factor: 12.479

View more