Literature DB >> 12209785

The use of microscale processing technologies for quantification of biocatalytic Baeyer-Villiger oxidation kinetics.

Steven D Doig1, Samuel C R Pickering, Gary J Lye, John M Woodley.   

Abstract

Microscale processing techniques would be a useful tool for the rapid and efficient collection of biotransformation kinetic data as a basis for bioprocess design. Automated liquid handling systems can reduce labor intensity while the small scale reduces the demand for scarce materials such as substrate, product, and biocatalyst. Here we illustrate this concept by establishing the use of several microwell formats (96-round, 96-deep square and 24-round well microtiter plates) for quantification of the kinetics of the E. coli TOP10 [pQR239] resting cell catalyzed Baeyer-Villiger oxidation of bicyclo[3.2.0]hept-2en-6-one using glycerol as a source of reducing power. By increasing the biocatalyst concentration until the biotransformation rate was oxygen mass-transfer limited we can ensure that kinetic data collected are in the region away from oxygen limitation. Using a 96-round well plate the effect of substrate (bicyclo[3.2.0]hept-2en-6-one) concentration on the volumetric CHMO activity was examined and compared to data collected from 1.5-L stirred-tank experiments. The phenomenon and magnitude of substrate inhibition, observed at the larger scale, was accurately reproduced in the microwell format. We have used this as an illustrative example to demonstrate that under adequately defined conditions, automated microscale processing technologies can be used for the collection of quantitative kinetic data. Additionally, by using the experimentally determined stoichiometry for product formation and glycerol oxidation, we have estimated the maximum oxygen transfer rates as a function of well geometry and agitation rate. Oxygen-transfer rates with an upper limit of between 33 mmol. L(-1). h(-1) (based solely on product formation) and 390 mmol. L(-1). h(-1) (based on product formation and glycerol oxidation) were achieved using a 96-square well format plate shaken at 1300 rpm operated with a static surface area to volume ratio of 320 m(2). m(-3). Copyright 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 80: 42-49, 2002.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12209785     DOI: 10.1002/bit.10344

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  5 in total

1.  New approaches to augment fungal biotransformation.

Authors:  Balajee Shanmugam; Scott Luckman; Mia Summers; Valerie Bernan; Michael Greenstein
Journal:  J Ind Microbiol Biotechnol       Date:  2003-04-24       Impact factor: 3.346

Review 2.  Miniaturization in biocatalysis.

Authors:  Pedro Fernandes
Journal:  Int J Mol Sci       Date:  2010-03-02       Impact factor: 5.923

3.  A stepwise approach for the reproducible optimization of PAMO expression in Escherichia coli for whole-cell biocatalysis.

Authors:  Edwin van Bloois; Hanna M Dudek; Wouter A Duetz; Marco W Fraaije
Journal:  BMC Biotechnol       Date:  2012-06-21       Impact factor: 2.563

4.  Screening of Supports for the Immobilization of β-Glucosidase.

Authors:  Joelise de Alencar Figueira; Fernanda Furlan Gonçalves Dias; Hélia Harumi Sato; Pedro Fernandes
Journal:  Enzyme Res       Date:  2011-09-11

5.  Biocatalyst Screening with a Twist: Application of Oxygen Sensors Integrated in Microchannels for Screening Whole Cell Biocatalyst Variants.

Authors:  Ana C Fernandes; Julia M Halder; Bettina M Nestl; Bernhard Hauer; Krist V Gernaey; Ulrich Krühne
Journal:  Bioengineering (Basel)       Date:  2018-04-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.