Literature DB >> 12208709

Artisan phakic intraocular lens for myopia:short-term results of a prospective, multicenter study.

Robert K Maloney1, Lien H Nguyen, Maurice E John.   

Abstract

PURPOSE: To evaluate the safety and efficiency of the Artisan iris-supported phakic intraocular lens (Ophtec BV, Groningen, Netherlands) for the correction of high myopia. STUDY
DESIGN: Nonrandomized, prospective, multicenter trial conducted under a United States Food and Drug Administration (FDA) Investigational Device Exemption. PARTICIPANTS: One hundred fifty-five eyes of 155 patients with myopia from -5.5 to -22.5 diopters (D) underwent implantation of an Artisan lens, as part of a phase I, II, or III FDA trial.
METHODS: Eyes were examined at 1 day (154 eyes), 2 weeks (142 eyes), 2 months (130 eyes), and 6 months (84 eyes). Intraocular pressure and presence of flare and cell on slit-lamp biomicroscopy were recorded at each visit. MAIN OUTCOME MEASURES: Achieved correction, stability of spherical equivalent refraction, change in astigmatism, postoperative uncorrected vision, change in best spectacle-corrected acuity, and change in endothelial cell count.
RESULTS: Mean spherical equivalent manifest refraction stabilized on postoperative day 1. Mean difference between attempted and achieved correction at 2 months was -0.32 +/- 0.95 D (mean +/- standard deviation; range, -4.42 to +2.2 D). At 6 months, 85% of eyes saw 20/40 or better uncorrected, and 90% of eyes were within 1 D of the attempted correction. Refractive astigmatism increased in 4.8% of eyes and decreased in 17% of eyes at 6 months. At 2 months, six eyes (4.8%) lost two or more lines of best spectacle-corrected visual acuity; by 6 months, no eyes lost two or more lines of best-corrected visual acuity. Endothelial cell count was unchanged at 6 months compared with the preoperative count. Nonprogressive lens opacities developed in four eyes as a result of surgical trauma. Chronic inflammation was not detected in any eye by slit-lamp biomicroscopy, nor did any eye develop angle closure or glaucoma.
CONCLUSIONS: Short-term results suggest that the Artisan lens is an accurate and safe method for the correction of high myopia. Surgical skill is important in avoiding lens opacities. Longer-term data are needed to assess the impact of the lens on the endothelium, the crystalline lens, and the iris.

Entities:  

Mesh:

Year:  2002        PMID: 12208709     DOI: 10.1016/s0161-6420(02)01170-3

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  19 in total

1.  [Higher order aberrations after implantation of an iris claw pIOL (Ophtec Artisan) in the phakic eye].

Authors:  J Bühren; T Kasper; E Terzi; T Kohnen
Journal:  Ophthalmologe       Date:  2004-12       Impact factor: 1.059

Review 2.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

Review 3.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 4.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

5.  Correction of high myopia with different phakic anterior chamber intraocular lenses: ICARE angle-supported lens and Verisyse iris-claw lens.

Authors:  Stanislawa Gierek-Ciaciura; Ariadna Gierek-Lapinska; Krzysztof Ochalik; Ewa Mrukwa-Kominek
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-07-01       Impact factor: 3.117

6.  Artisan phakic intraocular lens for correcting high myopia.

Authors:  Tova Lifshitz; Jaime Levy; Isaac Aizenman; Itamar Klemperer; Shmuel Levinger
Journal:  Int Ophthalmol       Date:  2005-09-29       Impact factor: 2.031

7.  Effect of incision types for Artisan phakic intraocular lens implantation on ocular higher order aberrations.

Authors:  Young Min Park; Bong Joon Choi; Jong Soo Lee
Journal:  Int J Ophthalmol       Date:  2016-12-18       Impact factor: 1.779

8.  Visual outcomes after lensectomy and iris claw artisan intraocular lens implantation in patients with Marfan syndrome.

Authors:  Hossein Mohammad Rabie; Parviz Malekifar; Mohammad Ali Javadi; Danial Roshandel; Hamed Esfandiari
Journal:  Int Ophthalmol       Date:  2016-10-05       Impact factor: 2.031

9.  Long-term endothelial cell loss with the iris-claw intraocular phakic lenses (Artisan®).

Authors:  Virgilio Galvis; John F Villamil; María Fernanda Acuña; Paul A Camacho; Jesús Merayo-Lloves; Alejandro Tello; Sandra Lizeth Zambrano; Juan José Rey; Juan Vicente Espinoza; Angélica María Prada
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-10-28       Impact factor: 3.117

10.  Five-year follow-up after anterior iris-fixated intraocular lens implantation in phakic eyes to correct high myopia.

Authors:  X Yuan; H Z Ping; W C Hong; D Yin; Z Ting
Journal:  Eye (Lond)       Date:  2011-12-02       Impact factor: 3.775

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.