Literature DB >> 12208404

Effectiveness of rheolytic coronary thrombectomy with the AngioJet catheter.

Stéphane Rinfret1, Peter T Katsiyiannis, Kalon K L Ho, David J Cohen, Donald S Baim, Joseph P Carrozza, Roger J Laham.   

Abstract

Thrombus-filled lesions are associated with a higher rate of acute complications and long-term restenosis following conventional coronary or saphenous vein graft (SVG) intervention. To evaluate the clinical effectiveness of rheolytic thrombectomy in a nonselected population in the glycoprotein IIb/IIIa blockade era, we reviewed clinical, angiographic, and procedural data on 119 patients who underwent 126 consecutive coronary AngioJet procedures (29% in SVGs, and 71% in native coronary arteries) from July 1998 to August 2000. Glycoprotein IIb/IIIa blockers were used in 88%. Most vessels (68% of SVGs, 74% of native coronary arteries) were occluded initially. Complete or substantial removal of filling defects was achieved in 76% of SVGs and 66% of native coronary cases. The AngioJet rheolytic thrombectomy device led to significant improvement in lumen diameter and Thrombolysis In Myocardial Infarction (TIMI) flow, with reduction in the thrombotic lesion length (p <0.05). Angiographic success (<30% residual stenosis, TIMI-3) was attained in 73% of SVGs and 87% of native coronary procedures. Distal embolization occurred in 13 cases, and was less likely to occur in patients treated with abciximab (0%) compared with patients treated with other glycoprotein IIb/IIIa blockers or heparin alone (17%, p = 0.02). A favorable response to the AngioJet (odds ratio 3.9) and freedom from embolization (odds ratio 14.6) were associated with a higher procedural success rate. In-hospital and long-term clinical outcomes were favorable. Thus, rheolytic thrombectomy resulted in significant reduction of the thrombus burden in most patients, restored TIMI-3 flow, and led to favorable short- and long-term outcomes.

Entities:  

Mesh:

Year:  2002        PMID: 12208404     DOI: 10.1016/s0002-9149(02)02516-x

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  Transradial intracoronary catheter-aspiration embolectomy for acute coronary embolism after mitral valve replacement.

Authors:  Wei-Chin Hung; Chiung-Jen Wu; Wei-Jen Chen; Cheng-Hsu Yang; Jen-Ping Chang
Journal:  Tex Heart Inst J       Date:  2003

2.  Safety and efficacy of thrombectomy in patients undergoing primary percutaneous coronary intervention for acute ST elevation MI: a meta-analysis of randomized controlled trials.

Authors:  Umesh U Tamhane; Stanley Chetcuti; Irfan Hameed; P Michael Grossman; Mauro Moscucci; Hitinder S Gurm
Journal:  BMC Cardiovasc Disord       Date:  2010-02-26       Impact factor: 2.298

  2 in total