Literature DB >> 12206589

Detection of marginal defects of composite restorations with conventional and digital radiographs.

Rainer Haak1, Michael J Wicht, Martin Hellmich, Michael J Noack.   

Abstract

The purpose of this study was to determine the validity of detecting approximal imperfections of composite fillings using three intraoral radiographic systems in vitro. Class II composite resin restorations (108) with three radiopacities (264, 306, 443% Al 99.5) of which 27 had marginal openings or overhangs, respectively, were conventionally (Ektaspeed plus) and digitally (Dexis, Digora) radiographed. Images were assessed by 10 observers for the presence of marginal gaps and overhangs, as well as for their need of restorative treatment according to a five-point confidence rating scale. The validity of the observations were expressed as areas under receiver operating characteristic (ROC) curves (Aroc). Repeated measures analysis of variance revealed significant effects of 'radiographic system' and 'diagnostic purpose'. Marginal overhangs (Aroc = 0.90) were significantly easier to diagnose than openings (Aroc = 0.63). Marginal gaps were better detected on conventional and Dexis radiographs than on Digora images. the range of sensitivities and specificities of the treatment decision was 0.53-0.56 and 0.87-0.88, respectively. It was concluded that the validity of detecting marginal defects of composite resin restorations based on radiographs was only slightly affected by the radiographic system being used. The diagnosis of marginal gaps frequently resulted in false-positive and false-negative decisions.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12206589     DOI: 10.1034/j.1600-0722.2002.21271.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  3 in total

1.  Influence of materials radiopacity in the radiographic diagnosis of secondary caries: evaluation in film and two digital systems.

Authors:  Ricardo Ferreira Pedrosa; I V Brasileiro; M L dos Anjos Pontual; A dos Anjos Pontual; M M F da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

2.  In vitro comparison of high-definition US, CBCT and periapical radiography in the diagnosis of proximal and recurrent caries.

Authors:  Oya Şeker; Kıvanç Kamburoğlu; Cihan Şahin; Nejlan Eratam; Esra Ece Çakmak; Gül Sönmez; Doğukan Özen
Journal:  Dentomaxillofac Radiol       Date:  2021-05-12       Impact factor: 2.419

3.  Evaluation of Newly Introduced Bioactive Materials in Terms of Cavity Floor Adaptation: OCT Study.

Authors:  Heba B Abdel-Maksoud; Aziza W Bahanan; Lujain J Alkhattabi; Turki A Bakhsh
Journal:  Materials (Basel)       Date:  2021-12-12       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.