Successful treatment of a femoral artery pseudoaneurysm mimicking a deep venous thrombosis following cardiac catheterization.

Gregory M Gauthier1, Robert S Dieter.   

Abstract

Access site pseudoaneurysms are uncommon but well-known complications of cardiac catheterization. We report the first known case of a pseudoaneurysm mimicking the presentation of a deep venous thrombosis by causing extrinsic compression of the venous system. The patient had complete resolution of the pseudoaneurysm and his symptoms following treatment with ultrasound-guided percutaneous thrombin injection. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12203934     DOI: 10.1002/ccd.10279

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  1 in total

1.  Ultrasound in evaluation of post-interventional femoral vein obstruction: a case report.

Authors:  Mai Tone Lønnebakken; Eva Gerdts; Jan Wirsching; Ole Martin Pedersen
Journal:  Cardiovasc Ultrasound       Date:  2009-03-26       Impact factor: 2.062