A combined ion source for fast switching between electrospray and matrix-assisted laser desorption/ionization in Fourier transform ion cyclotron resonance mass spectrometry.

Gökhan Baykut1, Jens Fuchser, Matthias Witt, Gerhard Weiss, Christoph Gosteli.   

Abstract

A new ion source has been developed for Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) that enables quick changes between matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) modes. When operating as an ESI source, the sample solution is sprayed through an angled nebulizer. The generated ions pass through a glass capillary followed by a skimmer and three sequential hexapole ion guides. Ions can be accumulated in the third hexapole (storage hexapole) before they are injected into the ICR trap. The second hexapole is mounted on a movable platform which also carries the MALDI sample plate. During the switch from ESI to MALDI, this platform moves the second hexapole out of the hexapole series and locates a MALDI sample plate with 384 sample positions into the area directly in front of the storage hexapole. The storage hexapole is in a medium pressure chamber (MPC) which has windows both for the incoming laser beam and for the observation optics, as well as a gas tube for pulsing collision gas into the chamber. During the MALDI operation the focused laser beam enters the MPC, passes between the hexapole rods and irradiates a MALDI sample on the target plate. The sample molecules are desorbed/ionized into the storage hexapole and simultaneously cooled by collisions with the pulsed gas. Ions desorbed from multiple laser shots can be accumulated in this hexapole before they are transferred to the ICR trap. With the combined ion source a computer-controlled switch between MALDI and ESI modes is possible in less than a minute, depending on the position of the MALDI target on the 384-spot plate. Immediate acquisition of mass spectra is possible after mode switching without the need for tuning or re-calibration. Copyright 2002 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12203230     DOI: 10.1002/rcm.759

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

1.  Fourier transform ion cyclotron resonance mass spectrometry with NanoLC/microelectrospray ionization and matrix-assisted laser desorption/ionization: analytical performance in peptide mass fingerprint analysis.

Authors:  Matthias Witt; Jens Fuchser; Gökhan Baykut
Journal:  J Am Soc Mass Spectrom       Date:  2003-06       Impact factor: 3.109

2.  A liquid injection field desorption/ionization-electrospray ionization combination source for a fourier transform ion cyclotron resonance mass spectrometer.

Authors:  H Bernhard Linden; Jürgen H Gross
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-18       Impact factor: 3.109

3.  An external matrix-assisted laser desorption ionization source for flexible FT-ICR Mass spectrometry imaging with internal calibration on adjacent samples.

Authors:  Donald F Smith; Konstantin Aizikov; Marc C Duursma; Frans Giskes; Dirk-Jan Spaanderman; Liam A McDonnell; Peter B O'Connor; Ron M A Heeren
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-20       Impact factor: 3.109

4.  On-tissue localization of ceramides and other sphingolipids by MALDI mass spectrometry imaging.

Authors:  E Ellen Jones; Shaalee Dworski; Daniel Canals; Josefina Casas; Gemma Fabrias; Drew Schoenling; Thierry Levade; Chadrick Denlinger; Yusuf A Hannun; Jeffrey A Medin; Richard R Drake
Journal:  Anal Chem       Date:  2014-08-08       Impact factor: 6.986

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.