Literature DB >> 12201456

Diagnostic ultrasound-induced membrane damage in phagocytic cells loaded with contrast agent and its relation to Doppler-mode images.

Douglas L Miller1, Jawaid Quddus.   

Abstract

Cell membrane damage induced by diagnostic ultrasound exposure with contrast agent was examined and related to the display of stimulated acoustical emission in Doppler images. Monolayers of mouse macrophage-like cells were cultured on the inside of one window of an exposure chamber. The monolayers were incubated with 5% Optison (Mallinckrodt, Inc., St. Louis, MO) for 15 minutes then rinsed to remove unattached gas bodies. A Spectra Plus scanner (Diasonics GE Medical Systems, Inc., Cincinnati, OH) in B-scan or Doppler-imaging modes exposed the chamber 3.5 cm away in a 37 degrees C water bath. The cells were scored either for uptake of fluorescent Dextran (sonoporation), or for trypan blue dye exclusion (cell death). No significant effect was seen for exposure in any mode without a contrast agent. Significant effects with contrast agent included 5.8% (2.3% standard deviation, SD) fluorescent cells and 33.4% (7.7% SD) trypan blue-stained cells in Doppler-imaging modes, compared to 0.0% and 2.2% (1.7% SD), respectively, in sham exposures. Frames of the power Doppler image were analyzed for pixel brightness to quantify the brief flash in the Doppler window. Although both membrane damage and the flash brightness increased with increasing pressure amplitude, there did not appear to be a direct correlation between the two phenomena.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12201456     DOI: 10.1109/tuffc.2002.1026021

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  4 in total

1.  Contributions of mechanical and sonochemical effects to cell membrane damage induced by single-shot pulsed ultrasound with adjacent microbubbles.

Authors:  Kengo Okada; Nobuki Kudo; Takashi Kondo; Katsuyuki Yamamoto
Journal:  J Med Ultrason (2001)       Date:  2008-12-16       Impact factor: 1.314

2.  Changes in cell morphology due to plasma membrane wounding by acoustic cavitation.

Authors:  Robyn K Schlicher; Joshua D Hutcheson; Harish Radhakrishna; Robert P Apkarian; Mark R Prausnitz
Journal:  Ultrasound Med Biol       Date:  2010-04       Impact factor: 2.998

3.  Ultrasound molecular imaging of tumor angiogenesis with an integrin targeted microbubble contrast agent.

Authors:  Christopher R Anderson; Xiaowen Hu; Hua Zhang; Jose Tlaxca; Anne-Emilie Declèves; Robert Houghtaling; Kumar Sharma; Michael Lawrence; Katherine W Ferrara; Joshua J Rychak
Journal:  Invest Radiol       Date:  2011-04       Impact factor: 6.016

4.  Explorations of high-intensity therapeutic ultrasound and microbubble-mediated gene delivery in mouse liver.

Authors:  S Song; Z Shen; L Chen; A A Brayman; C H Miao
Journal:  Gene Ther       Date:  2011-03-31       Impact factor: 5.250

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.