Literature DB >> 12200834

Determination of SCN- in urine and saliva of smokers and non-smokers by SCN(-)-selective polymeric membrane containing a nickel(II)-azamacrocycle complex coated on a graphite electrode.

Mohammad Reza Ganjali1, Mohammad Yousefi, Mehran Javanbakht, Tahereh Poursaberi, Masoud Salavati-Niasari, Leila Hajiagha-Babaei, Elnaz Latifi, Mojtaba Shamsipur.   

Abstract

The construction, performance characteristics, and application of a novel polymeric membrane coated on a graphite electrode with unique selectivity towards SCN- are reported. The electrode was prepared by incorporating Ni(II)-2,2,4,9,9,11-hexamethyltetraazacyclotetradecanediene perchlorate into a plasticized poly(vinyl chloride) membrane. The influences of membrane composition, pH and foreign ions were investigated. The electrode displays a near Nernstian slope (-57.8 mV decade-1) over a wide concentration range of 1 x 10(-7)-1 x 10(-1) M of SCN- ion. The electrode has a detection limit of 4.8 x 10(-8) M (2.8 ng/cm3) SCN- and shows response times of about 15 s and 120 s for low to high and high to low concentration sequences, respectively. The proposed sensor shows high selectivity towards SCN- over several common organic and inorganic anions. The electrode revealed a great enhancement in selectivity coefficients and detection limit for SCN-, in comparison with the previously reported electrodes. It was successfully applied to the direct determination of SCN- in milk and biological samples, and as an indicator electrode in titration of Ag+ ions with thiocyanate.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12200834     DOI: 10.2116/analsci.18.887

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  3 in total

Review 1.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade.

Authors:  Farnoush Faridbod; Parviz Norouzi; Rassoul Dinarvand; Mohammad Reza Ganjali
Journal:  Sensors (Basel)       Date:  2008-04-03       Impact factor: 3.576

2.  Schiff's Bases and Crown Ethers as Supramolecular Sensing Materials in the Construction of Potentiometric Membrane Sensors.

Authors:  Farnoush Faridbod; Mohammad Reza Ganjali; Rassoul Dinarvand; Parviz Norouzi; Siavash Riahi
Journal:  Sensors (Basel)       Date:  2008-03-11       Impact factor: 3.576

3.  Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva.

Authors:  Marcin Urbanowicz; Kamila Sadowska; Dorota Pijanowska; Radosław Pomećko; Maria Bocheńska
Journal:  Sensors (Basel)       Date:  2020-05-15       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.