Intra- and inter-observer reliability of the distal metatarsal articular angle in adult hallux valgus.

Thomas D Chi1, James Davitt, Alastair Younger, Sarah Holt, Bruce J Sangeorzan.   

Abstract

There is some uncertainty as to whether the distal metatarsal articular angle (DMAA) is a real entity or just radiographic artifact and whether it can be reliably measured. If it is intrinsic to the bone, it should not change with bone position. If it is clinically useful, it should be reproducible. Pre-operative and post-operative radiographs of 32 patients undergoing a proximal bony procedure of the first ray were evaluated independently by three foot and ankle specialists in order to determine the intra and inter-observer reliability of the distal metatarsal articular angle (DMAA). In addition, the hallux valgus angle (HVA), intermetatarsal angle (IMA) and joint congruency/subluxation were determined. We used ANOVA (Scheffe's F-test) to determine reliability of the angular measurements; a p value of less than 0.05 indicates poor reliability and a p value of greater than 0.05 indicates reliability. Intra-observer reliability was good for all angular measurements (HVA, IMA, DMAA pre-op, and DMAA post-op) with p values ranging from 0.33 to 0.95. Inter-observer reliability of the HVA and IMA was good (p=0.63 and p=0.32). Inter-observer reliability of the pre-op DMAA approached statistically poor reliability (p=0.09) and the post-op DMAA reliability was poor (p=0.002). The DMAA reduced after the proximal procedure as measured by all observers, and averaged a reduction of 3.9 degrees. Weighted kappa analysis also revealed that there was poor agreement in the determination of congruency and subluxation (Kappa statistic ranged from 0.07 to 0.19). This study suggests that there may be limited value in the DMAA as a clinical measure as it varies with examiner and with the hallux valgus angle.

Entities:  

Mesh:

Year:  2002        PMID: 12199386     DOI: 10.1177/107110070202300808

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  7 in total

1.  A minimally invasive technique for surgical treatment of hallux valgus: simple, effective, rapid, inexpensive (SERI).

Authors:  Sandro Giannini; Cesare Faldini; Matteo Nanni; Alberto Di Martino; Deianira Luciani; Francesca Vannini
Journal:  Int Orthop       Date:  2013-07-03       Impact factor: 3.075

2.  The Scarf osteotomy: a salvage procedure for recurrent hallux valgus in selected cases.

Authors:  Peter Bock; Ulrich Lanz; Andreas Kröner; Georg Grabmeier; Alfred Engel
Journal:  Clin Orthop Relat Res       Date:  2010-05-22       Impact factor: 4.176

3.  Reliability of different smartphones measuring the hallux valgus parameters in a new rapid method: a follow-up study.

Authors:  Lin Wang; Chao Zhang; Hao Liang; Jun Zhang; Weiyang Zhong; Zenghui Zhao; Tianji Huang; Xiaoji Luo
Journal:  BMC Musculoskelet Disord       Date:  2022-04-02       Impact factor: 2.362

4.  Distal Chevron Osteotomy vs The Simple, Effective, Rapid, Inexpensive Technique (SERI) for Mild to Moderate Isolated Hallux Valgus: A Randomized Controlled Study.

Authors:  Ezequiel Palmanovich; N Ohana; Segal David; I Small; I Hetsroni; E Amar; Z T Sharfman; D Segal; R Atzmon
Journal:  Indian J Orthop       Date:  2020-08-08       Impact factor: 1.251

5.  A geometric analysis of hallux valgus: correlation with clinical assessment of severity.

Authors:  Carlos Piqué-Vidal; Joan Vila
Journal:  J Foot Ankle Res       Date:  2009-05-14       Impact factor: 2.303

6.  Hallux valgus angle as main predictor for correction of hallux valgus.

Authors:  Axel R Deenik; Enrico de Visser; Jan-Willem K Louwerens; Maarten de Waal Malefijt; Frits F Draijer; Rob A de Bie
Journal:  BMC Musculoskelet Disord       Date:  2008-05-15       Impact factor: 2.362

7.  The excessive length of first ray as a risk factor for hallux valgus recurrence.

Authors:  Xingchen Li; Min Guo; Yuan Zhu; Xiangyang Xu
Journal:  PLoS One       Date:  2018-10-10       Impact factor: 3.240