Literature DB >> 12199119

The intra- and inter-examiner reliability of quantitative light-induced fluorescence (QLF) analyses.

I A Pretty1, A F Hall, P W Smith, W M Edgar, S M Higham.   

Abstract

OBJECTIVE: To assess the reliability of the analysis stage of quantitative light-induced fluorescence (QLF). The QLF analysis involves subjective input from the user and this study examines the influence of this on the reproducibility of the QLF data.
METHOD: QLF images were taken of 20 human molar teeth that had been previously subjected to a demineralizing solution (phosphoric acid 37%) to create artificial white spot lesions on their buccal surfaces. Following examination of the images, 16 were chosen to represent a range of lesion size and severity. Three copies were made of the images and each was allocated a different filename. 10 examiners in three centres were asked to analyse each of the 16 images on three occasions, with at least seven days between each attempt. Simple instructions describing the analysis procedure were supplied and examiners were asked to adhere to these directions. Examiners were asked to rate each of the 16 teeth on their first attempt both quantitatively (5 point scale) and qualitatively in terms of difficulty of analysis. Data reported were the delta Q at 5% threshold for each tooth on each of three attempts.
RESULTS: Using ANOVA and paired t-tests to detect statistical differences, the three attempts of each examiner were used to determine intra-examiner reliability. Only one examiner (a novice at the technique) demonstrated differences between all three attempts and two demonstrated difference between one attempt. When the mean scores were compared to determine the inter-examiner reliability, only one examiner's results were statistically different when compared with two others.
CONCLUSION: This study has demonstrated that the analysis stage of QLF is reliable between examiners and within multiple attempts by the same examiner, when analysing in vitro lesions. Novices at the technique should be trained before analysing experimental data.

Entities:  

Mesh:

Year:  2002        PMID: 12199119     DOI: 10.1038/sj.bdj.4801496

Source DB:  PubMed          Journal:  Br Dent J        ISSN: 0007-0610            Impact factor:   1.626


  8 in total

1.  Performance of a new fluorescence camera for detection of occlusal caries in vitro.

Authors:  Anahita Jablonski-Momeni; Fabian Liebegall; Richard Stoll; Monika Heinzel-Gutenbrunner; Klaus Pieper
Journal:  Lasers Med Sci       Date:  2012-03-21       Impact factor: 3.161

2.  The evaluation of a novel method comparing quantitative light-induced fluorescence (QLF) with spectrophotometry to assess staining and bleaching of teeth.

Authors:  A A Adeyemi; F D Jarad; E de Josselin de Jong; N Pender; S M Higham
Journal:  Clin Oral Investig       Date:  2009-03-21       Impact factor: 3.573

3.  Performance of a fluorescence camera for detection of occlusal caries in vitro.

Authors:  Anahita Jablonski-Momeni; Helge Marten Schipper; Simon Martin Rosen; Monika Heinzel-Gutenbrunner; Matthias Johannes Roggendorf; Richard Stoll; Vitus Stachniss; Klaus Pieper
Journal:  Odontology       Date:  2011-01-27       Impact factor: 2.634

4.  Demineralization adjacent to orthodontic brackets after application of conventional and self-etching primer systems.

Authors:  D Visel; Theresa Jäcker; T Jäcker; P-G Jost-Brinkmann; T-M Präger
Journal:  J Orofac Orthop       Date:  2014-08-28       Impact factor: 1.938

5.  Quantitative light-induced fluorescence images and digital photographs - Reproducibility of manually marked demineralisations.

Authors:  Rosalia Tatano; Eva E Ehrlich; Benjamin Berkels; Ekaterina Sirazitdinova; Thomas M Deserno; Ulrike B Fritz
Journal:  J Orofac Orthop       Date:  2017-02-20       Impact factor: 1.938

6.  Assessment of a new infrared laser transillumination technology (808 nm) for the detection of occlusal caries-an in vitro study.

Authors:  D G Bussaneli; M Restrepo; T Boldieri; H Pretel; M W Mancini; L Santos-Pinto; R C L Cordeiro
Journal:  Lasers Med Sci       Date:  2014-12-31       Impact factor: 3.161

7.  Comparison of Quantitative light-induced fluorescence-digital (QLF-D) images and images of disclosed plaque for planimetric quantification of dental plaque in multibracket appliance patients.

Authors:  Katharina Klaus; Tabea Glanz; Alexander Georg Glanz; Carolina Ganss; Sabine Ruf
Journal:  Sci Rep       Date:  2020-03-11       Impact factor: 4.379

8.  Application of quantitative light-induced fluorescence to determine the depth of demineralization of dental fluorosis in enamel microabrasion: a case report.

Authors:  Tae-Young Park; Han-Sol Choi; Hee-Won Ku; Hyun-Su Kim; Yoo-Jin Lee; Jeong-Bum Min
Journal:  Restor Dent Endod       Date:  2016-06-20
  8 in total