An international collaborative study was organised to replace the 2nd International Standard (IS) for tissue plasminogen activator (tPA). The 2nd IS for tPA (86/670) was used to calibrate the replacement Standard, which was selected from two candidate materials included in the collaborative study. Participants were provided with five sets of four samples (A, B, C, D) and asked to use sample A (2nd IS, 86/670, 850 IU/ml) to determine the activity of B (86/624, approximately 850 IU/ml), C and D (coded duplicates of the same material, 98/714 approximately 11,000 IU/ml). A total of 14 laboratories returned results from Europe, USA, Japan and Australia, providing data from 60 independent assays. Four laboratories used a reference method based on a published monograph from the European Pharmacopoeia for Alteplase for Injection, 1998, and the remaining 10 used their own method. Fibrin was used as promoter of tPA activity by 12 out of the 14 laboratories, the remaining two used kits where fibrinogen fragments were the promoter. Data from this collaborative study and the previous study to establish the 2nd IS for tPA show that tPA from melanoma cells and recombinant tPA from CHO cells are both suitable materials as International Standards. It was agreed that sample C, D, recombinant tPA, 98/714, be established as the 3rd International Standard for tPA with a potency of 10,000 IU per ampoule, calculated as the mean value from laboratories using fibrin as a promoter of tPA activity. The standard was established by WHO in November 2000.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12195703

Source DB:  PubMed          Journal:  Thromb Haemost        ISSN: 0340-6245            Impact factor:   5.249


  4 in total

1.  The interplay between tissue plasminogen activator domains and fibrin structures in the regulation of fibrinolysis: kinetic and microscopic studies.

Authors:  Colin Longstaff; Craig Thelwell; Stella C Williams; Marta M C G Silva; László Szabó; Krasimir Kolev
Journal:  Blood       Date:  2010-10-21       Impact factor: 22.113

2.  Mechanical stability and fibrinolytic resistance of clots containing fibrin, DNA, and histones.

Authors:  Colin Longstaff; Imre Varjú; Péter Sótonyi; László Szabó; Michael Krumrey; Armin Hoell; Attila Bóta; Zoltán Varga; Erzsébet Komorowicz; Krasimir Kolev
Journal:  J Biol Chem       Date:  2013-01-04       Impact factor: 5.157

3.  Development and implementation of tPA clot lysis activity assay using ACL TOP™ hemeostasis testing system in QC laboratories.

Authors:  Lichun Huang
Journal:  Biotechnol Rep (Amst)       Date:  2017-10-27

Review 4.  Measuring fibrinolysis: from research to routine diagnostic assays.

Authors:  C Longstaff
Journal:  J Thromb Haemost       Date:  2018-02-17       Impact factor: 5.824

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.