Literature DB >> 12194521

The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants.

W Kenneth Ward1, Emily P Slobodzian, Kenneth L Tiekotter, Michael D Wood.   

Abstract

We addressed the effect of implant thickness, implant porosity, and polyurethane (PU) chemistry on angiogenesis and on the foreign body response in rats. The following materials were implanted subcutaneously for 7 weeks then excised for histologic analysis: a solid PU; a solid polyurethane with silicone and polyethylene oxide (PU-S-PEO); porous expanded polytetrafluoroethylene (ePTFE); and porous polyvinyl alcohol sponge (PVA). Two thicknesses of PU-S-PEO were compared: 300 microns (thin) and 2000 microns (thick). Foreign body capsule (FBC) thickness was much less in PU-S-PEO implants than in PU implants. In addition, FBC were thinner in thin implants than in thick implants. FBC was much more dense in solid implants than in porous implants. As compared with solid implants, porous implants (PVA and ePTFE) led to a marked increase in the number of microvessels that developed adjacent to the implant, as observed both with hematoxylin/eosin staining and with an immunohistochemical anti-endothelial stain. We conclude that the polyethylene oxide and silicone moieties in PU reduce the thickness of the subsequent FBC. In addition, thin implants lead to a thin FBC. Porous implants (PVA and ePTFE) cause more angiogenesis than solid implants. These results may have implications for the measurement of blood-derived analytes by biosensors.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12194521     DOI: 10.1016/s0142-9612(02)00160-6

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  44 in total

1.  The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants.

Authors:  Scott P Nichols; Ahyeon Koh; Nga L Brown; Michael B Rose; Bin Sun; Danielle L Slomberg; Daniel A Riccio; Bruce Klitzman; Mark H Schoenfisch
Journal:  Biomaterials       Date:  2012-06-27       Impact factor: 12.479

Review 2.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

Review 3.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

Review 4.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response-part II: examples and application.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

5.  A review of the management of implanted medical devices for diabetes: trends and directions.

Authors:  Carl Edman; Darrel Drinan
Journal:  J Diabetes Sci Technol       Date:  2008-11

6.  A review of the foreign-body response to subcutaneously-implanted devices: the role of macrophages and cytokines in biofouling and fibrosis.

Authors:  W Kenneth Ward
Journal:  J Diabetes Sci Technol       Date:  2008-09

7.  In vivo evaluation of titanium oxide and hydroxyapatite as an artificial cornea skirt.

Authors:  Xiao Wei Tan; Roger W Beuerman; Zhi Long Shi; Koon Gee Neoh; Donald Tan; Khiam Aik Khor; Jodhbir S Mehta
Journal:  J Mater Sci Mater Med       Date:  2012-03-17       Impact factor: 3.896

8.  Controlling fibrous capsule formation through long-term down-regulation of collagen type I (COL1A1) expression by nanofiber-mediated siRNA gene silencing.

Authors:  Pim-on Rujitanaroj; Brian Jao; Junghoon Yang; Feng Wang; James M Anderson; Jun Wang; Sing Yian Chew
Journal:  Acta Biomater       Date:  2012-10-02       Impact factor: 8.947

Review 9.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

10.  In vitro and in vivo characterization of porous poly-L-lactic acid coatings for subcutaneously implanted glucose sensors.

Authors:  H E Koschwanez; F Y Yap; B Klitzman; W M Reichert
Journal:  J Biomed Mater Res A       Date:  2008-12-01       Impact factor: 4.396

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.