Literature DB >> 12194343

Heavy ion RBE and microdosimetric spectra.

R Gerlach1, H Roos, A M Kellerer.   

Abstract

Reliable values for the relative biological effectiveness (RBE) of the complex field of heavy ions is essential for radiation therapy with carbon beams. Clinical experience with this novel form of therapy is still quite narrow and it is, therefore, desirable to compare and combine relevant clinical findings and theoretical approaches. One major source of available information comes from neutron therapy. The approach towards the determination of RBE for neutron therapy is, therefore, tentatively applied to the heavy ion therapy. This includes the determination of microdosimetric spectra and their numerical evaluation towards the determination of RBE. A microdosimetric detector on the basis of a tissue-equivalent proportional counter (TEPC) was developed for measurements in the heavy ion fields of the GSI, Darmstadt. Measurements were performed first near the perspex phantom surface with carbon ion energies between 89 MeV.amu-1 and 430 MeV.amu-1. Subsequently, measurements were taken at various depths in the neighbourhood of the Bragg region. The numerical techniques that were developed for neutron therapy lead to tentative values of the RBE that are compared to the RBE values from the biophysical model developed at the GSI. The comparison is still preliminary but can be helpful in modifying the microdosimetric approach for its application in heavy ion therapy.

Entities:  

Mesh:

Year:  2002        PMID: 12194343     DOI: 10.1093/oxfordjournals.rpd.a006821

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Early effects of low dose C ion or x-ray irradiation on peripheral blood lymphocytes of patients with alimentary tract cancer.

Authors:  Yingtai Chen; Xuezhong Chen; Yumin Li; Hong Zhang; Yi Xie; Xiaowei Zhang; Huizi Ren; Yanling Wang; Shiqi Liao; Mingyan He; Jinyu Ren; Jieyu Zhang; Xiadong Zhou; Tongzhang Zheng; Briseis A Kilfoy; Yawei Zhang
Journal:  Dose Response       Date:  2010-08-02       Impact factor: 2.658

2.  Biodosimetry estimate for high-LET irradiation.

Authors:  Z Z Wang; W J Li; D J Zhi; X G Jing; W Wei; Q X Gao; B Liu
Journal:  Radiat Environ Biophys       Date:  2007-04-19       Impact factor: 1.925

3.  The microdosimetric extension in TOPAS: development and comparison with published data.

Authors:  Hongyu Zhu; Yizheng Chen; Wonmo Sung; Aimee L McNamara; Linh T Tran; Lucas N Burigo; Anatoly B Rosenfeld; Junli Li; Bruce Faddegon; Jan Schuemann; Harald Paganetti
Journal:  Phys Med Biol       Date:  2019-07-11       Impact factor: 3.609

4.  Early effects of low dos C ion or X-ray irradiation on human peripheral blood lymphocytes.

Authors:  Yingtai Chen; Yumin Li; Hong Zhang; Yi Xie; Xuezhong Chen; Jinyu Ren; Xiaowei Zhang; Zijiang Zhu; Hongliang Liu; Yawei Zhang
Journal:  Adv Space Res       Date:  2010-04-01       Impact factor: 2.152

5.  The origin of neutron biological effectiveness as a function of energy.

Authors:  G Baiocco; S Barbieri; G Babini; J Morini; D Alloni; W Friedland; P Kundrát; E Schmitt; M Puchalska; L Sihver; A Ottolenghi
Journal:  Sci Rep       Date:  2016-09-22       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.