Literature DB >> 12193995

Comparative analysis of pedicle screw and hook instrumentation in posterior correction and fusion of idiopathic thoracic scoliosis.

U Liljenqvist1, U Lepsien, L Hackenberg, T Niemeyer, H Halm.   

Abstract

Posterior correction and fusion with segmental hook instrumentation represent the gold standard in the surgical treatment of progressive idiopathic thoracic scoliosis. However, there is a debate over whether pedicle screws are safe in scoliosis surgery and whether their usage might enable a better curve correction and a shorter fusion length. The details of curve correction, fusion length and complication rate of 99 patients with idiopathic thoracic scoliosis treated with either hook or pedicle screw instrumentation were analyzed. Forty-nine patients had been operated with the Cotrel-Dubousset system using hooks exclusively ("hook group"). Fifty patients had been operated with either a combination of pedicle screws in the lumbar and lower thoracic and hooks in the upper thoracic spine or exclusive pedicle screw instrumentation using the Münster Posterior Double Rod System ("screw group"). The preoperative Cobb angle averaged 61.3 degrees (range 40 degrees-84 degrees ) in the hook group and 62.5 degrees (range 43 degrees-94 degrees ) in the screw group. Average primary curve correction was 51.7% in the hook group and 55.8% in the screw group ( P>0.05). However, at follow-up (2-12 years later) primary curve correction was significantly greater ( P=0.001) in the screw group (at 50.1%) compared to the hook group (at 41.1%). Secondary lumbar curve correction was significantly greater ( P=0.04) in the screw group (54.9%) compared to the hook group (46.9%). Correction of the apical vertebral rotation according to Perdriolle was minimal in both groups. Apical vertebral translation was corrected by 42.0% in the hook group and 55.6% in the screw group ( P=0.008). Correction of the tilt of the lowest instrumented vertebra averaged 48.1% in the hook group and 66.2% in the screw group ( P=0.0004). There were no differences concerning correction of the sagittal plane deformity between the two groups. Fusion length was, on average, 0.6 segments shorter in the screw group compared to the hook group ( P=0.03). With pedicle screws, the lowest instrumented vertebra was usually one below the lower end vertebra, whereas in the hook group it was between one and two vertebrae below the lower end vertebra. Both operative time and intraoperative blood loss were significantly higher in the hook group ( P<0.0001). One pedicle screw at T5 was exchanged due to the direct proximity to the aorta. There were no neurologic complications related to pedicle screw instrumentation. Pedicle screw instrumentation alone or in combination with proximal hook instrumentation offers a significantly better primary and secondary curve correction in idiopathic thoracic scoliosis and enables a significantly shorter fusion length.

Entities:  

Mesh:

Year:  2002        PMID: 12193995      PMCID: PMC3610482          DOI: 10.1007/s00586-002-0415-9

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  61 in total

1.  Quantitative three-dimensional anatomy of cervical, thoracic and lumbar vertebrae of Chinese Singaporeans.

Authors:  S H Tan; E C Teo; H C Chua
Journal:  Eur Spine J       Date:  2003-12-12       Impact factor: 3.134

2.  A biomechanical analysis of the self-retaining pedicle hook device in posterior spinal fixation.

Authors:  Wilbert van Laar; Rinse J Meester; Theo H Smit; Barend J van Royen
Journal:  Eur Spine J       Date:  2007-01-03       Impact factor: 3.134

3.  Intra and interobserver variability of preoperative planning for surgical instrumentation in adolescent idiopathic scoliosis.

Authors:  M Robitaille; C E Aubin; H Labelle
Journal:  Eur Spine J       Date:  2007-08-02       Impact factor: 3.134

4.  Variability of spinal instrumentation configurations in adolescent idiopathic scoliosis.

Authors:  Carl-Eric Aubin; Hubert Labelle; Oana C Ciolofan
Journal:  Eur Spine J       Date:  2006-02-14       Impact factor: 3.134

Review 5.  [Posterior operative correction of idiopathic scoliosis. Value of pedicle screws versus hooks].

Authors:  V Bullmann; U R Liljenqvist; C Schmidt; T L Schulte
Journal:  Orthopade       Date:  2009-02       Impact factor: 1.087

6.  Financial analysis of circumferential fusion versus posterior-only with thoracic pedicle screw constructs for main thoracic idiopathic curves between 70 degrees and 100 degrees.

Authors:  Scott J Luhmann; Lawrence G Lenke; Yongjung J Kim; Keith H Bridwell; Mario Schootman
Journal:  J Child Orthop       Date:  2008-02-14       Impact factor: 1.548

7.  In-vivo demonstration of the effectiveness of thoracoscopic anterior release using the fulcrum-bending radiograph: a report of five cases.

Authors:  Kenneth M C Cheung; Duo Sai Lu; Hou Zhang; Keith D K Luk
Journal:  Eur Spine J       Date:  2005-12-21       Impact factor: 3.134

8.  Skipped versus consecutive pedicle screw constructs for correction of Lenke 1 curves.

Authors:  Simon Morr; Alexandra Carrer; Luis Ignacio Alvarez-García de Quesada; Juan Carlos Rodriguez-Olaverri
Journal:  Eur Spine J       Date:  2015-01-20       Impact factor: 3.134

9.  Accuracy of pedicle screw insertion in posterior scoliosis surgery: a comparison between intraoperative navigation and preoperative navigation techniques.

Authors:  Wei Zhang; Tomoyuki Takigawa; YongGang Wu; Yoshihisa Sugimoto; Masato Tanaka; Toshifumi Ozaki
Journal:  Eur Spine J       Date:  2016-12-27       Impact factor: 3.134

Review 10.  [Characteristics of neuromuscular scoliosis].

Authors:  M Putzier; C Groß; R K Zahn; M Pumberger; P Strube
Journal:  Orthopade       Date:  2016-06       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.