Literature DB >> 12186716

Pressure drops in a distensible model of end-to-side anastomosis in systemic-to-pulmonary shunts.

Francesco Migliavacca1, Giancarlo Pennati, Elena Di Martino, Gabriele Dubini, Riccardo Pietrabissa.   

Abstract

The modified Blalock-Taussig shunt is a surgical procedure used as a palliation to treat complex congenital heart defects. It consists of an interposing prosthetic tube between the innominate/subclavian artery and the right pulmonary artery. Previous experience indicates that the pressure drop across the shunt is affected by the pulmonary pressure at the distal anastomosis combined with the distensibility of the anastomosis. In this study, a computational fluid-structure interaction approach is presented to investigate the haemodynamic behaviour. Steady-state fluid dynamics and structural analyses were carried out using commercial codes based on the finite element method (FIDAP and ABAQUS) coupled by means of a purposely-developed procedure to transfer boundary conditions. Both prosthetic tube and artery walls were characterised by non-linear material properties. Three different pulmonary pressures (2, 5 and 15 mmHg) and two volume flow rates (0.4 and 0.8 l/min) were investigated. Results indicate that the effects of distensibility at the distal anastomosis on the shunt pressure drop are relevant only when the distal anastomosis on the shunt pressure drop are relevant only when the distal anastomosis is not fully distended, which occurs when the pulmonary pressure is lower than 5 mmHg.

Entities:  

Mesh:

Year:  2002        PMID: 12186716     DOI: 10.1080/10255840290010689

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  6 in total

1.  Characterization of the highly nonlinear and anisotropic vascular tissues from experimental inflation data: a validation study toward the use of clinical data for in-vivo modeling and analysis.

Authors:  Kinon Chen; Bahar Fata; Daniel R Einstein
Journal:  Ann Biomed Eng       Date:  2008-07-29       Impact factor: 3.934

2.  Characterization of Post-Operative Hemodynamics Following the Norwood Procedure Using Population Data and Multi-Scale Modeling.

Authors:  Jonathan Primeaux; Arash Salavitabar; Jimmy C Lu; Ronald G Grifka; C Alberto Figueroa
Journal:  Front Physiol       Date:  2021-05-13       Impact factor: 4.566

Review 3.  Computational Analysis of the Pulmonary Arteries in Congenital Heart Disease: A Review of the Methods and Results.

Authors:  M Conijn; G J Krings
Journal:  Comput Math Methods Med       Date:  2021-04-01       Impact factor: 2.238

4.  Finite-element-method (FEM) model generation of time-resolved 3D echocardiographic geometry data for mitral-valve volumetry.

Authors:  Janko F Verhey; Nadia S Nathan; Otto Rienhoff; Ron Kikinis; Fabian Rakebrandt; Michael N D'Ambra
Journal:  Biomed Eng Online       Date:  2006-03-03       Impact factor: 2.819

5.  Feasibility of rapid and automated importation of 3D echocardiographic left ventricular (LV) geometry into a finite element (FEM) analysis model.

Authors:  Janko F Verhey; Nadia S Nathan
Journal:  Biomed Eng Online       Date:  2004-10-08       Impact factor: 2.819

Review 6.  Computational fluid dynamics models and congenital heart diseases.

Authors:  Giancarlo Pennati; Chiara Corsini; Tain-Yen Hsia; Francesco Migliavacca
Journal:  Front Pediatr       Date:  2013-02-26       Impact factor: 3.418

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.