Literature DB >> 12184618

Column selectivity in reversed-phase liquid chromatography I. A general quantitative relationship.

N S Wilson1, M D Nelson, J W Dolan, L R Snyder, R G Wolcott, P W Carr.   

Abstract

Retention factors k have been measured for 67 neutral, acidic and basic solutes of highly diverse molecular structure (size, shape, polarity, hydrogen bonding, pKa, etc.) on 10 different C18 columns (other conditions constant). These data have been combined with k values from a previous study (86 solutes, five different C8 and C18 columns) to develop a six-term equation for the correlation of retention as a function of solute and column. Values of k can be correlated with an accuracy of +/- 1-2% (1 standard deviation). This suggests that all significant contributions to column selectivity have been identified (and can be measured) for individual alkyl-silica columns which do not have an embedded polar group. That is, columns of the latter kind can be quantitatively characterized in terms of selectivity for use in the separation of any sample.

Entities:  

Mesh:

Year:  2002        PMID: 12184618     DOI: 10.1016/s0021-9673(02)00659-3

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  12 in total

1.  Application of silica-based hyper-crosslinked sulfonate-modified reversed stationary phases for separating highly hydrophilic basic compounds.

Authors:  Hao Luo; Lianjia Ma; Changyub Paek; Peter W Carr
Journal:  J Chromatogr A       Date:  2008-06-18       Impact factor: 4.759

2.  Novel ultra stable silica-based stationary phases for reversed phase liquid chromatography--study of a hydrophobically assisted weak acid cation exchange phase.

Authors:  Yu Zhang; Peter W Carr
Journal:  J Chromatogr A       Date:  2010-11-16       Impact factor: 4.759

3.  Retention projection enables accurate calculation of liquid chromatographic retention times across labs and methods.

Authors:  Daniel Abate-Pella; Dana M Freund; Yan Ma; Yamil Simón-Manso; Juliane Hollender; Corey D Broeckling; David V Huhman; Oleg V Krokhin; Dwight R Stoll; Adrian D Hegeman; Tobias Kind; Oliver Fiehn; Emma L Schymanski; Jessica E Prenni; Lloyd W Sumner; Paul G Boswell
Journal:  J Chromatogr A       Date:  2015-08-03       Impact factor: 4.759

Review 4.  Silica-based, hyper-crosslinked acid stable stationary phases for high performance liquid chromatography.

Authors:  Yu Zhang; Hao Luo; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-08-06       Impact factor: 4.759

5.  Synthesis and characterization of silica-based hyper-crosslinked sulfonate-modified reversed stationary phases.

Authors:  Hao Luo; Lianjia Ma; Yu Zhang; Peter W Carr
Journal:  J Chromatogr A       Date:  2007-12-07       Impact factor: 4.759

6.  Application of Snyder-Dolan classification scheme to the selection of "orthogonal" columns for fast screening of illicit drugs and impurity profiling of pharmaceuticals--I. Isocratic elution.

Authors:  Wenzhe Fan; Yu Zhang; Peter W Carr; Sarah C Rutan; Melanie Dumarey; Adam P Schellinger; Wayne Pritts
Journal:  J Chromatogr A       Date:  2009-08-06       Impact factor: 4.759

7.  A visual approach to stationary phase selectivity classification based on the Snyder-Dolan Hydrophobic-Subtraction Model.

Authors:  Yu Zhang; Peter W Carr
Journal:  J Chromatogr A       Date:  2009-06-21       Impact factor: 4.759

8.  Origin of the selectivity differences of aromatic alcohols and amines of different n-alkyl chain length separated with perfluorinated C8 and bidentated C8 modified silica hydride stationary phases.

Authors:  Chadin Kulsing; Yada Nolvachai; Maria T Matyska; Joseph J Pesek; Joshua Topete; Reinhard I Boysen; Milton T W Hearn
Journal:  Anal Chim Acta X       Date:  2018-12-28

Review 9.  Optimizing separations in online comprehensive two-dimensional liquid chromatography.

Authors:  Bob W J Pirok; Andrea F G Gargano; Peter J Schoenmakers
Journal:  J Sep Sci       Date:  2017-11-23       Impact factor: 3.645

10.  Sources of Nonlinear van't Hoff Temperature Dependence in High-Performance Liquid Chromatography.

Authors:  Maria Tanase; Andreia Soare; Victor David; Serban C Moldoveanu
Journal:  ACS Omega       Date:  2019-11-14
View more