Literature DB >> 12184415

Differential scanning calorimetric studies of nickel titanium rotary endodontic instruments.

W A Brantley1, T A Svec, M Iijima, J M Powers, T H Grentzer.   

Abstract

Differential scanning calorimetric (DSC) analyses were performed between -130 degrees and 100 degrees C on specimens prepared from nickel-titanium (NiTi) rotary endodontic instruments: ProFile (n = 5), Lightspeed (n = 4), and Quantec (n = 3). The ProFile and Lightspeed instruments were in the as-received condition, whereas the Quantec instruments were randomly selected from a dental clinic and had unknown history. The DSC plots showed that the ProFile and Lightspeed instruments analyzed had the superelastic NiTi property, with an austenite-finish (Af) temperature of approximately 25 degrees C. Differences in DSC plots for the ProFile instruments and the starting wire blanks (n = 2) were attributed to the manufacturing process. The phase transformation behavior when the specimens were heated and cooled between -130 degrees and 100 degrees C, the temperature ranges for the phase transformations, and the resulting enthalpy changes were similar to those previously reported for nickel-titanium orthodontic wires having superelastic characteristics or shape memory behavior in the oral environment. The experiments demonstrated that DSC is a powerful tool for materials characterization of these rotary instruments, providing direct information not readily available from other analytical techniques about the NiTi phases present, which are fundamentally responsible for their clinical behavior.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12184415     DOI: 10.1097/00004770-200208000-00001

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  3 in total

Review 1.  Endodontic Rotary Files, What Should an Endodontist Know?

Authors:  Ana-Belén Dablanca-Blanco; Pablo Castelo-Baz; Ramón Miguéns-Vila; Pablo Álvarez-Novoa; Benjamín Martín-Biedma
Journal:  Medicina (Kaunas)       Date:  2022-05-27       Impact factor: 2.948

2.  Advancing Nitinol: From heat treatment to surface functionalization for nickel-titanium (NiTi) instruments in endodontics.

Authors:  Wai-Sze Chan; Karan Gulati; Ove A Peters
Journal:  Bioact Mater       Date:  2022-09-27

Review 3.  Metallurgical Tests in Endodontics: A Narrative Review.

Authors:  Alessio Zanza; Marco Seracchiani; Rodolfo Reda; Gabriele Miccoli; Luca Testarelli; Dario Di Nardo
Journal:  Bioengineering (Basel)       Date:  2022-01-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.