Literature DB >> 12182294

Immediate mandibular rehabilitation with endosseous implants: simultaneous extraction, implant placement, and loading.

Lyndon F Cooper1, Amin Rahman, John Moriarty, Nancy Chaffee, Debra Sacco.   

Abstract

PURPOSE: This report of a clinical patient series indicates the relative safety and illustrates the procedures involved in the extraction of remaining teeth followed by immediate implant placement and loading with a simple acrylic resin fixed denture.
MATERIALS AND METHODS: Ten consecutive patients who selected tooth extraction and implant-supported fixed denture rehabilitation of the mandible were treated using a 1-visit approach for extraction, implant placement, and restoration. Healthy individuals (10 women) were treated under local anesthesia. Fifty-four implants were placed in 10 patients. Five or 6 Astra Tech implants (11 or 13 mm long) were placed into the edentulous parasymphyseal region of the mandible. Four to 6 implants (48 of 54) were immediately loaded by the fabrication of a simple acrylic resin fixed denture. The criterion for loading was clinical judgment of primary stability, ie, the absence of axial or lateral mobility with physical resistance to rotation. Patients were recalled at 1, 3, and 12 weeks. At 12 weeks, impressions were made for the fabrication of a screw-retained fixed denture. The fixed dentures were completed using conventional fabrication and prosthetic techniques.
RESULTS: After a period of 6 to 18 months, all 54 implants had survived and were considered 100% successful by independent testing of mobility and radiographic evidence of osseointegration. There were no surgical complications. Fracture and debonding of the acrylic resin provisional denture occurred for 1 patient during the first 12 weeks of treatment. DISCUSSION: Advantages to extraction with simultaneous replacement include the maintenance of vertical dimension, elimination of reline procedures and interim denture therapy, and potential improvement of soft tissue healing.
CONCLUSION: This therapeutic approach simplifies patient care without apparent additional risk.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12182294

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  11 in total

1.  Towards the limit of quantifying low-amplitude strains on bone and in coagulum around immediately loaded oral implants in extraction sockets.

Authors:  Murat Cavit Cehreli; Ayhan Comert; Murat Akkocaoglu; Ibrahim Tekdemir; Kivanc Akca
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

2.  Immediate implant placement: a case report.

Authors:  A Chandra Sekar; M Praveen; Aarti Saxena; A Gautam
Journal:  J Indian Prosthodont Soc       Date:  2012-06-02

3.  A comparative study on 7-year results of "All-on-Four™" immediate-function concept for completely edentulous mandibles: metal-ceramic vs. bar-retained superstructures.

Authors:  Mustafa Ayna; Aydin Gülses; Yahya Acil
Journal:  Odontology       Date:  2017-03-20       Impact factor: 2.634

4.  Injectable bone substitute to preserve alveolar ridge resorption after tooth extraction: a study in dog.

Authors:  D Boix; P Weiss; O Gauthier; J Guicheux; J-M Bouler; P Pilet; G Daculsi; G Grimandi
Journal:  J Mater Sci Mater Med       Date:  2006-11-22       Impact factor: 3.896

5.  Computer-Guided Implant Surgery in Fresh Extraction Sockets and Immediate Loading of a Full Arch Restoration: A 2-Year Follow-Up Study of 14 Consecutively Treated Patients.

Authors:  M Daas; A Assaf; K Dada; J Makzoumé
Journal:  Int J Dent       Date:  2015-05-12

6.  2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

Authors:  Shrikar R Desai; Rika Singh; I Karthikeyan
Journal:  J Indian Soc Periodontol       Date:  2013-09

7.  Immediate Functional Loading: Results for the Concept of the Strategic Implant®.

Authors:  Aleksandar Lazarov
Journal:  Ann Maxillofac Surg       Date:  2019 Jan-Jun

8.  Comparative evaluation of two types of immediately loaded implants using biomechanical and histomorphometric tests: an animal case study.

Authors:  Mansour Rismanchian; Bijan Movahedian; Navid Khalighinejad; Hamid Badrian; Sayed Mohammad Razavi; Afsaneh Nekouie
Journal:  ISRN Dent       Date:  2012-07-18

9.  Immediate function on the day of surgery compared with a delayed implant loading process in the mandible: a randomized clinical trial over 5 years.

Authors:  Asbjorn Jokstad; Hassan Alkumru
Journal:  Clin Oral Implants Res       Date:  2013-10-23       Impact factor: 5.977

10.  Immediately Loaded Bicortical Implants Inserted in Fresh Extraction and Healed Sites in Patients with and Without a History of Periodontal Disease.

Authors:  Łukasz R Pałka; Aleksandar Lazarov
Journal:  Ann Maxillofac Surg       Date:  2019 Jul-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.