Literature DB >> 12181368

Applications for multifrequency ultrasound biomicroscopy in mice from implantation to adulthood.

Y Q Zhou1, F S Foster, D W Qu, M Zhang, K A Harasiewicz, S L Adamson.   

Abstract

A new multifrequency (19-55 MHz) ultrasound biomicroscope with two-dimensional imaging and integrated Doppler ultrasound was evaluated using phantoms and isoflurane-anesthetized mice. Phantoms revealed the biomicroscope's lateral resolution was between 50 and 100 microm, whereas that of a conventional 13 MHz ultrasound system was 200-500 microm. This difference was apparent in the markedly higher resolution images achieved using the biomicroscope in vivo. Transcutaneous images of embryos in pregnant mice from approximately 2 days after implantation (7 days gestation) to near term (17.5 days) were obtained using frequencies from 25 to 40 MHz. The ectoplacental cone and early embryonic cavities were visible as were the placenta and embryonic organs throughout development to term. We also evaluated the ability of the biomicroscope to detect important features of heart development by examining embryos from 8.5 to 17.5 day gestation in exteriorized uteri using 55 MHz ultrasound. Cardiac looping, division of the outflow tract, and ventricular septation were visible. In postnatal imaging, we observed the heart and kidney of neonatal mice at 55 MHz, the carotid artery in juveniles (approximately 8 g body wt) and adults (approximately 25 g body wt) at 40 MHz, and the adult heart, aorta, and kidney at 19 MHz. The coefficient of variation of carotid and aortic diameter measurements was 1-3%. In addition, blisters in GRIP1 -/- embryos and aortic valvular stenosis in two adults were readily visualized. Using image-guided Doppler function, low blood velocities in vessels as small as 100 microm in diameter including the primitive heart tube at day 8.5 were measurable, but high blood velocities (>37.5 cm/s) such as in the heart and large arteries in late gestation and postnatal life were off-scale. Accurate cardiac dimension measurements were impeded by poor temporal resolution (4 frames/s). In summary, the multifrequency ultrasound biomicroscope is a versatile tool well suited to detailed study of the morphology of various organ systems throughout development in mice and for hemodynamic measurements in the low velocity range.

Entities:  

Mesh:

Year:  2002        PMID: 12181368     DOI: 10.1152/physiolgenomics.00119.2001

Source DB:  PubMed          Journal:  Physiol Genomics        ISSN: 1094-8341            Impact factor:   3.107


  27 in total

1.  Micro-ultrasound for preclinical imaging.

Authors:  F Stuart Foster; John Hossack; S Lee Adamson
Journal:  Interface Focus       Date:  2011-06-08       Impact factor: 3.906

2.  Non-invasive in vivo measurement of cardiac output in C57BL/6 mice using high frequency transthoracic ultrasound: evaluation of gender and body weight effects.

Authors:  Elisabet Domínguez; Jesús Ruberte; José Ríos; Rosa Novellas; Maria Montserrat Rivera Del Alamo; Marc Navarro; Yvonne Espada
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-23       Impact factor: 2.357

3.  Biomechanics of early cardiac development.

Authors:  Sevan Goenezen; Monique Y Rennie; Sandra Rugonyi
Journal:  Biomech Model Mechanobiol       Date:  2012-07-04

4.  Micromachining techniques in developing high-frequency piezoelectric composite ultrasonic array transducers.

Authors:  Changgeng Liu; Frank T Djuth; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-12       Impact factor: 2.725

5.  Ultrasonographic diagnosis of pregnancy in rats.

Authors:  Petros Ypsilantis; Savvas Deftereos; Panagiotis Prassopoulos; Constantinos Simopoulos
Journal:  J Am Assoc Lab Anim Sci       Date:  2009-11       Impact factor: 1.232

6.  Ovarian imaging in the mouse using ultrasound biomicroscopy (UBM): a validation study.

Authors:  Carmen N Mircea; Marla E Lujan; Rajesh S Jaiswal; Jaswant Singh; Gregg P Adams; Roger A Pierson
Journal:  Reprod Fertil Dev       Date:  2009       Impact factor: 2.311

7.  A flexible annular-array imaging platform for micro-ultrasound.

Authors:  Weibao Qiu; Yanyan Yu; Hamid Reza Chabok; Cheng Liu; Fu Keung Tsang; Qifa Zhou; K Kirk Shung; Hairong Zheng; Lei Sun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-01       Impact factor: 2.725

Review 8.  Translational paradigms in scientific and clinical imaging of cardiac development.

Authors:  Chelsea L Gregg; Jonathan T Butcher
Journal:  Birth Defects Res C Embryo Today       Date:  2013-06

9.  Homozygous missense N629D hERG (KCNH2) potassium channel mutation causes developmental defects in the right ventricle and its outflow tract and embryonic lethality.

Authors:  Guo Qi Teng; Xian Zhao; James P Lees-Miller; F Russell Quinn; Pin Li; Derrick E Rancourt; Barry London; James C Cross; Henry J Duff
Journal:  Circ Res       Date:  2008-10-23       Impact factor: 17.367

10.  LRRC10 is required to maintain cardiac function in response to pressure overload.

Authors:  Matthew J Brody; Li Feng; Adrian C Grimes; Timothy A Hacker; Timothy M Olson; Timothy J Kamp; Ravi C Balijepalli; Youngsook Lee
Journal:  Am J Physiol Heart Circ Physiol       Date:  2015-11-25       Impact factor: 4.733

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.