Literature DB >> 12176155

Flow cytometry assay for intracellular rabies virus detection.

Juliano Bordignon1, Silvia Cardoba Pires Ferreira, Graciane Maria Medeiros Caporale, Maria Luiza Carrieri, Ivanete Kotait, Hermênio Cavalcante Lima, Carlos Roberto Zanetti.   

Abstract

Following previous studies reporting microbiological diagnosis by flow cytometry, the possibility of using this method was examined to monitor infection of susceptible cell lines by a fixed rabies virus strain (Pasteur Virus strain-PV) or a wild rabies virus strain (WRS). Suspensions of BHK-21 and C6 cells were infected with viruses and a time course of virus infection was established. Sequentially, at several time points, infected and control uninfected cells were fixed, permeabilized, and stained with a rabies virus-specific antibody conjugate. This was achieved by resuspending cells in a solution containing p-formaldehyde in FACS lysis fluid, which allowed the detection of intracellular virus with flourescein-coupled antibodies by flow cytometry. A Becton Dickinson FACSCalibur flow cytometer was used to analyze the percentage of cells infected and the kinetics of the infection process was determined. As early as 12 h after inoculation with both rabies virus strains, significant levels (P<0.01) of infection (from 4.7 to 7.1%) were detected by flow cytometry. The maximum level of infection was obtained at 48 h in C6 cells (88%) with both viruses. The advantages of this method for examination of intracellular virus infection are discussed.

Entities:  

Mesh:

Year:  2002        PMID: 12176155     DOI: 10.1016/s0166-0934(02)00064-2

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  6 in total

1.  Development of monoclonal antibodies suitable for rabies virus antibody and antigen detection.

Authors:  Vishal Chander; R P Singh; P C Verma
Journal:  Indian J Virol       Date:  2012-09-26

2.  Detection of infective poliovirus by a simple, rapid, and sensitive flow cytometry method based on fluorescence resonance energy transfer technology.

Authors:  Jason L Cantera; Wilfred Chen; Marylynn V Yates
Journal:  Appl Environ Microbiol       Date:  2009-11-20       Impact factor: 4.792

3.  Flow cytometry-based assay for titrating dengue virus.

Authors:  C R Lambeth; L J White; R E Johnston; A M de Silva
Journal:  J Clin Microbiol       Date:  2005-07       Impact factor: 5.948

4.  Use of flow cytometry for rapid, quantitative detection of poliovirus-infected cells via TAT peptide-delivered molecular beacons.

Authors:  Divya Sivaraman; Hsiao-Yun Yeh; Ashok Mulchandani; Marylynn V Yates; Wilfred Chen
Journal:  Appl Environ Microbiol       Date:  2012-11-16       Impact factor: 4.792

5.  Quantitative measurement of varicella-zoster virus infection by semiautomated flow cytometry.

Authors:  Irina V Gates; Yuhua Zhang; Cindy Shambaugh; Meredith A Bauman; Charles Tan; Jean-Luc Bodmer
Journal:  Appl Environ Microbiol       Date:  2009-02-05       Impact factor: 4.792

6.  A Cell-Based Capture Assay for Rapid Virus Detection.

Authors:  Elad Milrot; Efi Makdasi; Boaz Politi; Tomer Israely; Orly Laskar
Journal:  Viruses       Date:  2020-10-15       Impact factor: 5.048

  6 in total