Literature DB >> 12174348

Miniaturized transesophageal echocardiography in newborn infants.

Charles J Bruce1, Patrick O'Leary, Donald J Hagler, James B Seward, Allison K Cabalka.   

Abstract

BACKGROUND AND METHODS: A miniaturized 5.5 to 10 MHz, phased-array, single longitudinal plane transducer mounted on a 3.3-mm diameter catheter (miniaturized transesophageal echocardiography [TEE]) may overcome mechanical limitations of standard pediatric transesophageal probes. We evaluated whether the miniaturized TEE probe could define clinically relevant anatomy in 17 infants who weighed less than 6 kg.
RESULTS: Twenty-two studies were performed in 17 infants without complication, weighing 2.1 to 5.6 kg. Twenty of twenty-two studies were diagnostic. Pediatric biplane TEE was not possible in 13 studies. Lack of horizontal plane imaging with miniaturized TEE made evaluation difficult in patients with atrioventricular septal defect.
CONCLUSION: Miniaturized TEE provided diagnostic intraoperative TEE in the majority of infants studied and may allow broader and safer application of TEE to neonates and small infants.

Entities:  

Mesh:

Year:  2002        PMID: 12174348     DOI: 10.1067/mje.2002.120978

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  6 in total

1.  Transoesophageal ultrasonography: a new approach to imaging the thoracic aorta.

Authors:  J B Chambers; P R Taylor; J F Reidy; C Woods; S J Carter; T S Padayachee
Journal:  Heart       Date:  2005-02       Impact factor: 5.994

2.  Intraoperative transesophageal echocardiogram using an intracardiac ultrasound catheter in a congenital heart surgery: a case report.

Authors:  P Costa; C Moura; J C Areias; A R Sousa
Journal:  Pediatr Cardiol       Date:  2012-08-02       Impact factor: 1.655

Review 3.  Intracardiac echocardiography in congenital heart disease.

Authors:  Piers C A Barker
Journal:  J Cardiovasc Transl Res       Date:  2009-01-23       Impact factor: 4.132

4.  Initial experience with a miniaturized multiplane transesophageal probe in small infants undergoing cardiac operations.

Authors:  Sinai C Zyblewski; Girish S Shirali; Geoffrey A Forbus; Tain-Yen Hsia; Scott M Bradley; Andrew M Atz; Meryl S Cohen; Eric M Graham
Journal:  Ann Thorac Surg       Date:  2010-06       Impact factor: 4.330

5.  Preliminary evaluation of a microtransesophageal probe in neonates and young infants undergoing surgery for congenital heart disease.

Authors:  Sreeja Pavithran; Kanagarajan Natarajan; Bijesh Vishwambaran; Avinash Dayalal Arke; Kothandam Sivakumar
Journal:  Ann Pediatr Cardiol       Date:  2014-09

Review 6.  What is new in pediatric cardiac imaging?

Authors:  Luc Mertens; Javier Ganame; Bénédicte Eyskens
Journal:  Eur J Pediatr       Date:  2007-07-10       Impact factor: 3.183

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.