Comparison of two stabilizer concepts for off-pump coronary artery bypass grafting.

Christian Detter1, Tobias Deuse, Frank Christ, Dieter H Boehm, Hermann Reichenspurner, Bruno Reichart.   

Abstract

BACKGROUND: This study was designed to evaluate the efficacy of two different stabilizer concepts for off-pump coronary artery bypass grafting.
METHODS: Between 2000 and 2001, 100 consecutive patients who underwent off-pump coronary artery bypass grafting were randomly assigned to two stabilization systems: the Medtronic Octopus 3 (n = 50) and the Genzyme Immobilizer (n = 50). During operation, two-dimensional cardiac surface motion was assessed by intravital microscopy using orthogonal polarization spectral imaging in 20 vessels at the anterior wall. Postoperative angiography of 47 vessels revealed anastomotic quality.
RESULTS: Patient demographics were similar in both groups regarding age, sex, ejection fraction, and New York Heart Association functional class. In 7 patients the randomized Immobilizer was rejected by the surgeon for lateral or posterior wall revascularization and subsequently switched to the Octopus device. Patients received 1.8 +/- 0.7 grafts in the Octopus and 1.6 +/- 0.5 in the Immobilizer group (p = not significant). Two-dimensional cardiac surface motion was significantly less using the Immobilizer (109.7 +/- 32.4 microm versus 423.5 +/- 129.6 microm; p < 0.001). Time required for anastomosis was significantly shorter in the Immobilizer group (11.3 +/- 3.5 versus 14.9 +/- 2.4 minutes; p < 0.001). Postoperative angiography showed no vessel occlusions but two anastomotic stenoses in each group.
CONCLUSIONS: Both stabilizers have been shown useful for off-pump coronary artery bypass grafting. The Immobilizer system showed better epicardial immobilization of the anterior wall resulting in shorter anastomosis times. However, because the Octopus 3 handling is more flexible and allows easier access to all vessels, it is the device of choice for posterior wall revascularization in our institution.

Entities:  

Mesh:

Year:  2002        PMID: 12173835     DOI: 10.1016/s0003-4975(02)03734-7

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  1 in total

1.  Hemodynamic Changes During Heart Displacement in Aorta No-Touch Off-Pump Coronary Artery Bypass Surgery: A Pilot Study.

Authors:  Alexandre R Carvalho; Solange Guizilini; Gustavo M Murai; Isis Begot; Isadora S Rocco; Nelson A Hossne; Eduardo G Chamlian; João Manoel T Santos; Ricardo A Macedo; Gustavo C O Lisboa; Alberto C Nasciutti; Carlos Eduardo R Santos; João Paulo M Figueiredo; Walter J Gomes
Journal:  Braz J Cardiovasc Surg       Date:  2018 Sep-Oct
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.