Literature DB >> 12172591

In vivo high-resolution MR imaging of the carpal tunnel at 8.0 tesla.

Shella Farooki1, Carol J Ashman, Joseph S Yu, Amir Abduljalil, Donald Chakeres.   

Abstract

OBJECTIVE: To determine the feasibility of acquiring in vivo images of the human carpal tunnel at 8 tesla (T).
DESIGN: The wrist of an asymptomatic volunteer was imaged with an 8 T /80 cm magnet. The subject was imaged prone with the arm over the head and the wrist placed in neutral position in a custom-built dedicated shielded wrist coil. Axial two-dimensional gradient-echo (GRE) images of the wrist were acquired.
RESULTS: Image contrast and resolution at 8 T are excellent. The infrastructure of the median nerve, particularly the interfascicular epineurium and individual fascicles, is better visualized at 8 T than at 1.5 T. The flexor tendons are well delineated from each other and the surrounding soft tissues, and tertiary tendon fiber bundles are resolved. The boundaries of the carpal tunnel are better defined at 8 T.
CONCLUSION: We have obtained the first high-quality in vivo images of the human carpal tunnel at 8 T. The 8 T images demonstrated better contrast and resolution than those obtained at 1.5 T.

Entities:  

Mesh:

Year:  2002        PMID: 12172591     DOI: 10.1007/s00256-002-0506-z

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  8 in total

1.  MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience.

Authors:  Alberto Tagliafico; Giulia Succio; Carlo Emanuele Neumaier; Giovanni Serafini; Matteo Ghidara; Massimo Calabrese; Carlo Martinoli
Journal:  Skeletal Radiol       Date:  2010-10-23       Impact factor: 2.199

Review 2.  Muskuloskeletal MR imaging at 3.0 T: current status and future perspectives.

Authors:  Nicolae Bolog; Daniel Nanz; Dominik Weishaupt
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

3.  MR imaging of the human hand and wrist at 7 T.

Authors:  Björn Behr; Jörg Stadler; Henrik J Michaely; Hans-Georg Damert; Wolfgang Schneider
Journal:  Skeletal Radiol       Date:  2009-03-10       Impact factor: 2.199

4.  MRI of the wrist at 7 tesla using an eight-channel array coil combined with parallel imaging: preliminary results.

Authors:  Gregory Chang; Klaus M Friedrich; Ligong Wang; Renata L R Vieira; Mark E Schweitzer; Michael P Recht; Graham C Wiggins; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2010-03       Impact factor: 4.813

5.  Quantitative assessment of trabecular bone micro-architecture of the wrist via 7 Tesla MRI: preliminary results.

Authors:  Gregory Chang; Ligong Wang; Guoyuan Liang; James S Babb; Graham C Wiggins; Punam K Saha; Ravinder R Regatte
Journal:  MAGMA       Date:  2011-05-05       Impact factor: 2.310

6.  Vital signs investigation in subjects undergoing MR imaging at 8T.

Authors:  M Yang; G Christoforidis; A Abduljali; D Beversdorf
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

7.  Windows on the human body--in vivo high-field magnetic resonance research and applications in medicine and psychology.

Authors:  Ewald Moser; Martin Meyerspeer; Florian Ph S Fischmeister; Günther Grabner; Herbert Bauer; Siegfried Trattnig
Journal:  Sensors (Basel)       Date:  2010-06-08       Impact factor: 3.576

8.  In Vivo MR Microneurography of the Tibial and Common Peroneal Nerves.

Authors:  Paolo F Felisaz; Eric Y Chang; Irene Carne; Stefano Montagna; Francesco Balducci; Giulia Maugeri; Anna Pichiecchio; Fabrizio Calliada; Maurizia Baldi; Stefano Bastianello
Journal:  Radiol Res Pract       Date:  2014-12-07
  8 in total