Upper respiratory symptoms associated with aging of the ventilation system in artificially ventilated offices in São Paulo, Brazil.

Gustavo S Graudenz1, Jorge Kalil, Paulo H Saldiva, Walderez Gambale, Maria do Rosário D O Latorre, Fabio F Morato-Castro.   

Abstract

BACKGROUND: The increase of work-related respiratory complaints in artificially ventilated buildings has multiple causes, and the role of allergen exposure and symptoms is still controversial. STUDY
OBJECTIVES: To analyze the risk factors and the association of work-related symptoms with allergen exposure and different conditions of the same air conditioning system in São Paulo, Brazil.
DESIGN: Workers were classified according to characteristics of the air conditioning system: the first group (group 1) with ventilation machinery and ducts with > 20 years of use, the second group (group 2) with ventilation machinery with > 20 years of use and ventilation ducts with < 2 years of use, and the third group (group 3) with ventilation machinery and ducts with < 2 years of use. Logistic regression was performed to check the associations between air conditioning groups, allergen exposure (fungi, mites, animal dander, and cockroach), and symptoms.
RESULTS: There was a higher prevalence of building-related worsening of respiratory symptoms (p = 0.004; odds ratio [OR], 8.53) and symptoms of rhinoconjunctivitis (p = 0.01; OR, 8.49) in group 1. There was a lower relative humidity (p = 0.05) and nonsignificant lower temperature in group 1, when compared to the other groups. The viable mold spores totals were higher outdoors than in the indoor samples (n = 45, p = 0.017). There were higher levels of Der p 1 in group 2 (p = 0.032). All allergen levels were considered low.
CONCLUSION: There was a strong association of building-related upper-airway symptoms with places having ventilation systems with > 20 years of use.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12171858     DOI: 10.1378/chest.122.2.729

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  2 in total

1.  Infection risk in gyms during physical exercise.

Authors:  Alexandro Andrade; Fábio Hech Dominski; Marcelo Luiz Pereira; Carla Maria de Liz; Giorgio Buonanno
Journal:  Environ Sci Pollut Res Int       Date:  2018-05-07       Impact factor: 4.223

2.  Atopy, symptoms and indoor environmental perceptions, tear film stability, nasal patency and lavage biomarkers in university staff.

Authors:  Jan Vilhelm Bakke; Gunilla Wieslander; Dan Norbäck; Bente E Moen
Journal:  Int Arch Occup Environ Health       Date:  2007-12-08       Impact factor: 3.015

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.