Literature DB >> 12170200

Abdominal aortic aneurysm repair with the Zenith stent graft: short to midterm results.

Cherrie Z Abraham1, Timothy A M Chuter, Linda M Reilly, Stephen P Okuhn, Lisa K Pethan, Robert B Kerlan, Rajiv Sawhney, David G Buck, Roy L Gordon, Louis M Messina.   

Abstract

PURPOSE: The purpose of this study was to assess the short-term and mid-term results of endovascular aneurysm repair with the Zenith stent graft in a single-center prospective study.
METHOD: Between October 1998 and July 2001, we used the Zenith stent graft for elective endovascular aneurysm repair in 116 patients, six of whom were women. The mean age was 75 years, and the mean aneurysm diameter was 60.3 +/- 8.8 mm. Stent grafts were oversized 10% to 20% relative to computed tomographic (CT) scan-based diameter measurements. All repairs were performed in the operating room through surgically exposed femoral arteries. The results were assessed before discharge with three-phase, contrast-enhanced CT scan and plain abdominal radiograph. These studies were repeated at 1, 6, 12, and 24 months after operation. Follow-up periods ranged from 1 to 34 months.
RESULTS: No failed insertions and no conversions to open surgery occurred. The diameter of the main body of the stent graft was 28 mm or more in 73 patients (63%). Additional stents were inserted during surgery to treat kinking in eight patients (6.9%) and renal artery encroachment in two patients (1.7%). Mean fluoroscopy time was 35.1 +/- 18.3 minutes, contrast load was 146 +/- 53 mL (350 mg/mL), and estimated blood loss was 249 +/- 407 mL. The major complication rate was 9.5%, and the minor complication rate was 10.3%. The perioperative complications were myocardial infarction in four patients, arrythmia in four patients, and pulmonary embolism, renal failure, stroke, small bowel obstruction, femoral stenosis, digital embolism, and graft limb thrombosis in one patient each. All 116 patients went home from the hospital, but one patient died 2 weeks later of a combination of pulmonary embolism and myocardial infarction. Endoleak was seen on the first CT scan in 16 patients (15%); 15 were type II, and one was type III. No endoleaks of type I or IV were seen. Additional interventions were performed for each of the following conditions: type II endoleak (n = 4), type III endoleak (n = 1), femoral clamp injury (n = 1), renal artery stenosis (n = 1), and graft limb occlusion (n = 1). One patient had acute aneurysm dilatation and rupture caused by a type II endoleak through the inferior mesenteric artery 6 months after stent graft implantation. No cases were seen of late graft occlusion, stent graft migration, stent fracture, barb fracture, or secondary endoleak.
CONCLUSION: The Zenith device is safe, versatile, and effective in the short to medium term. Most patients need wide stent grafts (>or=28 mm proximally and >or=16 mm distally) to achieve 10% to 20% oversizing to prevent type I endoleak.

Entities:  

Mesh:

Year:  2002        PMID: 12170200     DOI: 10.1067/mva.2002.125032

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  7 in total

1.  Suprarenal fixation of endograft in abdominal aortic aneurysm treatment: focus on renal function.

Authors:  Franco Grego; Paolo Frigatti; Michele Antonello; Sandro Lepidi; Roberto Ragazzi; Vincenzo Iurilli; Pietro Zucchetta; Giovanni P Deriu
Journal:  Ann Surg       Date:  2004-07       Impact factor: 12.969

2.  In vivo deformation of the human abdominal aorta and common iliac arteries with hip and knee flexion: implications for the design of stent-grafts.

Authors:  Gilwoo Choi; Lewis K Shin; Charles A Taylor; Christopher P Cheng
Journal:  J Endovasc Ther       Date:  2009-10       Impact factor: 3.487

3.  Clinical significance of endoleaks characterized by computed tomography during aortography performed immediately after endovascular abdominal aortic aneurysm repair: prediction of persistent endoleak.

Authors:  Motoki Nakai; Hirotatsu Sato; Morio Sato; Yuko Tanba; Yasutaka Noda; Akira Ikoma; Hiroki Sanda; Kohei Nakata; Hiroki Minamiguchi; Nobuyuki Kawai; Tetsuo Sonomura; Kazushi Kishi; Yosiharu Nishimura; Yoshitaka Okamura
Journal:  Jpn J Radiol       Date:  2012-10-10       Impact factor: 2.374

4.  Late graft failure is rare after endovascular aneurysm repair using the Zenith stent graft in a cohort of high-risk patients.

Authors:  Joel L Ramirez; Melinda S Schaller; Bian Wu; Linda M Reilly; Timothy A M Chuter; Jade S Hiramoto
Journal:  J Vasc Surg       Date:  2019-05-27       Impact factor: 4.268

5.  Abdominal aortic aneurysm neck morphology: proposed classification system.

Authors:  C O McDonnell; M Halak; A Bartlett; S R Baker
Journal:  Ir J Med Sci       Date:  2006 Jul-Sep       Impact factor: 1.568

6.  Long-term outcomes of endovascular aortic aneurysm repair with the Zenith AAA endovascular graft: a single-center study.

Authors:  Hiroshi Kawamata; Hiroyuki Tajima; Tatsuo Ueda; Hidemasa Saito; Daisuke Yasui; Tadashi Kaneshiro; Naoko Takenoshita; Shouhei Mizushima; Takahiko Mine; Jiro Kurita; Yosuke Ishii; Tetsuro Morota; Takashi Nitta; Yuji Maruyama; Hajime Imura; Dai Nishina; Masahiro Fujii; Ryuzo Bessho
Journal:  Jpn J Radiol       Date:  2019-10-29       Impact factor: 2.374

7.  Endovascular abdominal aortic aneurysm repair in the geriatric population.

Authors:  Athanasios Saratzis; Saif Mohamed
Journal:  J Geriatr Cardiol       Date:  2012-09       Impact factor: 3.327

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.