Literature DB >> 12169846

The effect of profiled hemodialysis on intradialytic hemodynamics when a proper sodium balance is applied.

B Straver1, P M J M De Vries, A J M Donker, P M ter Wee.   

Abstract

BACKGROUND: Profiled hemodialysis (HD) has been claimed to ameliorate intradialytic complications such as hypotension. Frequently, these profiles are based on providing the patient with an accumulating sodium load. This increases the risk of interdialytic complications, such as hypertension and increased weight gain. The present study investigated the effect of profiled HD, without an accompanying sodium loading, on intradialytic hemodynamics in stable HD patients.
METHODS: In eight stable HD patients a standard hemodialysis (S-HD) was compared to a decreasing Na(+)-profiled hemodialysis (Na-HD), and an ultrafiltration profiled hemodialysis (UF-HD). Care was taken to have the sodium balances similar during these sessions. The patients were monitored non-invasively during dialysis with respect to their cardiac performance by means of electrical impedance cardiography, their variation in blood volume by means of an on-line optical measurement, and their hydration state by means of body impedance analysis.
RESULTS: Sodium balance and mean arterial sodium concentrations were similar in the three treatments. Intradialytic hemodynamics during UF-HD were similar to those of S-HD. However, Na-HD improved blood pressure preservation, remarkably without significant blood volume preservation, due to a better stroke volume preservation in the first hour of dialysis.
CONCLUSION: Sodium-balanced, Na-profiled HD improves blood pressure preservation in stable HD patients without providing the patients with a sodium load. This effect is due to a better stroke volume preservation early in dialysis, without a significant reduction in blood volume decrease. UF-HD, as mono-therapy, has no beneficial effect on intradialytic hemodynamics in stable patients. Copyright 2002 S. Karger AG, Basel

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12169846     DOI: 10.1159/000063105

Source DB:  PubMed          Journal:  Blood Purif        ISSN: 0253-5068            Impact factor:   2.614


  4 in total

1.  Evaluation of intradialytic hypotension using impedance cardiography.

Authors:  Abed Bayya; Dvora Rubinger; David Michael Linton; Sigal Sviri
Journal:  Int Urol Nephrol       Date:  2010-05-07       Impact factor: 2.370

2.  Effect of plasma sodium concentration on blood pressure regulators during hemodialysis: a randomized crossover study.

Authors:  Esmée M Ettema; Johanna Kuipers; Martijn van Faassen; Henk Groen; Arie M van Roon; Joop D Lefrandt; Ralf Westerhuis; Ido P Kema; Harry van Goor; Ron T Gansevoort; Carlo A J M Gaillard; Casper F M Franssen
Journal:  BMC Nephrol       Date:  2018-08-22       Impact factor: 2.388

3.  Effect of ultrafiltration profiling on outcomes among maintenance hemodialysis patients: a pilot randomized crossover trial.

Authors:  Jennifer E Flythe; Matthew J Tugman; Julia H Narendra; Magdalene M Assimon; Quefeng Li; Yueting Wang; Steven M Brunelli; Alan L Hinderliter
Journal:  J Nephrol       Date:  2020-09-25       Impact factor: 3.902

4.  Ultrafiltration-profiled hemodialysis to reduce dialysis-related cardiovascular stress: Study protocol for a randomized controlled trial.

Authors:  Matthew J Tugman; Julia H Narendra; Quefeng Li; Yueting Wang; Alan L Hinderliter; Steven M Brunelli; Jennifer E Flythe
Journal:  Contemp Clin Trials Commun       Date:  2019-07-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.