Literature DB >> 12169744

Lung function values in healthy non-smoking urban adults in iran.

M H Boskabady1, M Keshmiri, B Banihashemi, K Anvary.   

Abstract

BACKGROUND: The values of lung function tests (LFTs) are dependent on height, age, and sex. In addition, there is evidence of LFT variation in different ethnic groups.
OBJECTIVE: We have therefore derived prediction equations for LFTs from a healthy, non-smoking, urban adult population in the city of Mashhad (northeast Iran).
METHODS: Predicted equations for normal lung function have been derived from 572 healthy, non-smoking subjects including 326 men (height 154-195 cm) and 246 women (height 144-174 cm) aged 18-65 years. The subjects underwent measurement of spirometric flow and volume. The following variables were measured: forced vital capacity (FVC), forced expiratory volume in 1 s (FEV(1)), maximal mid-expiratory flow (MMEF), peak expiratory flow (PEF) and maximal expiratory flow at 75, 50 and 25% of the FVC (MEF(75), MEF(50), and MEF(25), respectively). Regression analysis using height and age as independent variables was applied to provide predicted values for both sexes.
RESULTS: There was a negative correlation between each lung function and age. The largest negative correlations were found for FEV(1) and FVC in men and women, respectively. All parameters correlated positively with height; the largest positive correlation was observed for FVC in both sexes. Comparison of LFTs derived from the equations of the present study showed significant differences with those of several previous studies.
CONCLUSION: In this study, a set of LFT reference values and prediction equations for both sexes have been derived using a relatively large, healthy, non-smoking Iranian, adult population which was different from several other prediction equations. Copyright 2002 S. Karger AG, Basel

Entities:  

Mesh:

Year:  2002        PMID: 12169744     DOI: 10.1159/000063271

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  6 in total

Review 1.  Spirometry.

Authors:  Theodore G Liou; Richard E Kanner
Journal:  Clin Rev Allergy Immunol       Date:  2009-04-04       Impact factor: 8.667

2.  Normal spirometric reference values for Omani adults.

Authors:  Omar A Al-Rawas; Sawasn Baddar; Abdullah A Al-Maniri; Jothi Balaji; B Jayakrishnan; Bazdawi M Al-Riyami
Journal:  Lung       Date:  2009-04-28       Impact factor: 2.584

3.  Estimation of lung vital capacity before and after coronary artery bypass grafting surgery: a comparison of incentive spirometer and ventilometry.

Authors:  Areli Cunha Pinheiro; Michelli Christina Magalhães Novais; Mansueto Gomes Neto; Marcus Vinicius Herbst Rodrigues; Erenaldo de Souza Rodrigues; Roque Aras; Vitor Oliveira Carvalho
Journal:  J Cardiothorac Surg       Date:  2011-05-12       Impact factor: 1.637

4.  Investigation on the lung function of general population in Ilam, west of Iran, as a city exposed to dust storm.

Authors:  Ali Amarloei; Ahmad Jonidi Jafari; Hassan Asilian Mahabadi; Kheirollah Asadollahi; Heshmatollah Nourmoradi
Journal:  Glob J Health Sci       Date:  2015-01-13

5.  Analysis of high predicted pulmonary function: possibility of overestimation in small elderly examinees.

Authors:  Youjin Chang; Ho Cheol Kim; Kyung-Wook Jo; Jae Seung Lee; Yeon-Mok Oh; Sang Do Lee; Sei Won Lee
Journal:  Korean J Intern Med       Date:  2019-10-17       Impact factor: 2.884

6.  Prediction equations for pulmonary function values in healthy children in Mashhad city, North East Iran.

Authors:  Syad Saleh Tabatabaie; Mohammad Hossein Boskabady; Sakinah Shah Mohammadi; Oranus Mohammadi; Prisa Saremi; Sediqa Amery; Hbibolah Esmaili; Zahra Ghafari; Marziah Boskabady
Journal:  J Res Med Sci       Date:  2014-02       Impact factor: 1.852

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.