OBJECTIVES: To document low sound levels, the range and pattern of levels, and the relative effects of operational (staff and equipment generated) and facility (building generated) noise on the acoustic environment of a level III nursery. STUDY
DESIGN: A quasi-experimental, prospective, longitudinal study of one bed space. Operational noise was reduced through staff behavior change while facility noise was reduced through renovation.
RESULTS: Initial noise levels were typical of those in the literature and in recently measured nurseries. About 80% of sound levels were between 62 and 70 dBA. The lowest levels (L(min)) were 60 to 65 dBA. After staff behavior change, L(min) was about 56 dBA although the highest levels (L(max)) remained at 78 to 100 dBA. Levels following renovation were reduced to L(min)s of 47 to 51 dBA and L(max)s of 68 to 84 dBA, perceived as three or four times quieter than initially.
CONCLUSIONS: Staff behavior as well as the acoustical characteristics of the facility determine the levels of noise and quiet in an intensive care nursery.

Entities:  

Mesh:

Year:  2002        PMID: 12168122     DOI: 10.1038/sj.jp.7210756

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  9 in total

Review 1.  The challenges of neonatal magnetic resonance imaging.

Authors:  Owen J Arthurs; Andrea Edwards; Topun Austin; Martin J Graves; David J Lomas
Journal:  Pediatr Radiol       Date:  2012-08-11

Review 2.  Breastfeeding Challenges and the Preterm Mother-Infant Dyad: A Conceptual Model.

Authors:  Chantal Lau
Journal:  Breastfeed Med       Date:  2017-10-19       Impact factor: 1.817

Review 3.  Exposure to maternal voice in preterm infants: a review.

Authors:  Charlene Krueger
Journal:  Adv Neonatal Care       Date:  2010-02       Impact factor: 1.968

Review 4.  Safe sound exposure in the fetus and preterm infant.

Authors:  Charlene Krueger; Elan Horesh; Brian Adam Crossland
Journal:  J Obstet Gynecol Neonatal Nurs       Date:  2012-03

5.  The Effect of Listening to Holy Quran Recitation on Weaning Patients Receiving Mechanical Ventilation in the Intensive Care Unit: A Pilot Study.

Authors:  Mohammad Yadak; Khalid Aziz Ansari; Hatem Qutub; Hajed Al-Otaibi; Omar Al-Omar; Nawal Al-Onizi; Faraz Ahmed Farooqi
Journal:  J Relig Health       Date:  2019-02

6.  Sound reduction management in the neonatal intensive care unit for preterm or very low birth weight infants.

Authors:  Abdulraoof Almadhoob; Arne Ohlsson
Journal:  Cochrane Database Syst Rev       Date:  2020-01-27

7.  The influence of APACHE II score on the average noise level in an intensive care unit: an observational study.

Authors:  Munhum Park; Pieter Vos; Björn N S Vlaskamp; Armin Kohlrausch; Annemarie W Oldenbeuving
Journal:  BMC Anesthesiol       Date:  2015-03-31       Impact factor: 2.217

8.  An acoustic gap between the NICU and womb: a potential risk for compromised neuroplasticity of the auditory system in preterm infants.

Authors:  Amir Lahav; Erika Skoe
Journal:  Front Neurosci       Date:  2014-12-05       Impact factor: 4.677

9.  Noise pollution in intensive care units and emergency wards.

Authors:  Gholamreza Khademi; Masoumeh Roudi; Ahmad Shah Farhat; Masoud Shahabian
Journal:  Iran J Otorhinolaryngol       Date:  2011
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.