Literature DB >> 12166817

Simultaneous determination of viloxazine, venlafaxine, imipramine, desipramine, sertraline, and amoxapine in whole blood: comparison of two extraction/cleanup procedures for capillary gas chromatography with nitrogen-phosphorus detection.

M A Martínez1, C Sánchez de la Torre, E Almarza.   

Abstract

A comparative study for the simultaneous gas chromatographic (GC) resolution and detection of the six antidepressants viloxazine, venlafaxine, imipramine, desipramine, sertraline, and amoxapine in whole blood at concentration levels of 100-2000 ng/mL was developed. Two extraction/cleanup analytical procedures were compared regarding their recovery, precision, sensitivity and matrix purification efficiency. The first procedure consists of the employment of Chem Elut columns (diatomaceous earth) and is based on the principle of liquid-solid absorption extraction that is closely related to conventional liquid-liquid extraction. The second focuses on the use of Bond Elut Certify columns and a mixed SPE, reversed-phase and cation-exchange sorbent, more recently developed for the market. Each procedure required 2.0 mL of whole blood extraction and injection into a capillary GC equipped with a nitrogen-phosphorus detector. Mepivacaine was used as the extraction standard (surrogate), and prazepam was used as the chromatographic standard. No interferences were found, and the time for the chromatographic analysis was 16 min for one sample. Recoveries of the compounds using Chem Elut columns at 500 ng/mL were in the range of 28-74% with intra-assay and interassay precisions of less than 7% and 19%, respectively. Limits of detection (LOD) and quantitation (LOQ) ranged from 39 to 153 ng/mL and from 128 to 504 ng/mL, respectively. Recoveries of the compounds using Bond Elut Certify columns at 500 ng/mL were in the range of 64-86% with intra-assay and interassay precisions of less than 4% and 10%, respectively. LODs and LOQs ranged from 21 to 100 ng/mL and from 70 to 330 ng/mL, respectively. An excellent linearity was observed with both procedures from the LOQs up to 2000 ng/mL. The use of the reversed-phase and cation-exchange sorbent Bond Elut Certify showed advantages compared with Chem Elut columns for the screening of these antidepressants such as higher recoveries, cleaner extracts, better sensitivity, better precision, and less solvent consumption and disposal.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12166817     DOI: 10.1093/jat/26.5.296

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  3 in total

1.  Application of microextraction by packed sorbent to isolation of psychotropic drugs from human serum.

Authors:  Renata Wietecha-Posłuszny; Aneta Garbacik; Michał Woźniakiewicz; Agnieszka Moos; Marcin Wieczorek; Paweł Kościelniak
Journal:  Anal Bioanal Chem       Date:  2011-10-16       Impact factor: 4.142

2.  Micellar electrokinetic chromatographic study of the separation of an aromatase inhibitor and a tryciclic antidepressant in the breast cancer treatment.

Authors:  J Rodríguez Flores; A M Contento Salcedo; L Muñoz Fernández
Journal:  Anal Chem Insights       Date:  2008-08-13

3.  Artificial Neural Networks (ANN) for the Simultaneous Spectrophotometric Determination of Fluoxetine and Sertraline in Pharmaceutical Formulations and Biological Fluid.

Authors:  Hamid Reza Akbari Hasanjani; Mahmoud Reza Sohrabi
Journal:  Iran J Pharm Res       Date:  2017       Impact factor: 1.696

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.