Continuous monitoring of the subcutaneous glucose level in freely moving normal and diabetic rats and in humans with type 1 diabetes.

Reza Jamali1, Johnny Ludvigsson, Simin Mohseni.   

Abstract

Laboratory animals are extensively used in diabetic research. However, it is not known whether the glucose dynamics in laboratory animals are similar to the dynamics in humans. The aim of the present study is to see whether the Medtronic MiniMed continuous subcutaneous glucose monitoring system can be used to record fluctuations of the glucose level in freely moving normal and insulin-treated diabetic rats. The monitoring system was applied during 3 days to normal and diabetic hyperglycemic and hypoglycemic rats treated with insulin implants. Corresponding data from type 1 diabetic patients with poor glycemic control were selected retrospectively in order to note the similarities and differences. In normal rats the subcutaneous glucose level varied slightly (median = 111 mg/dL). In hyperglycemic rats the subcutaneous glucose values fluctuated markedly around a median of 226 mg/dL. The fluctuations formed a short-wave pattern with a low amplitude, superimposed on a long-wave pattern with a high amplitude. The subcutaneous glucose profile seen in type 1 diabetic patients (median = 180 mg/dL) was similar to that observed in hyperglycemic rats. In hypoglycemic rats, the subcutaneous glucose level fluctuated moderately around a median of 55 mg/dL. In these rats the fluctuations formed a short-wave pattern with low amplitude, without any obvious long-wave pattern. The subcutaneous glucose values conformed to corresponding blood glucose measurements. We conclude that the Medtronic MiniMed continuous glucose monitoring system can be used to record the subcutaneous glucose level over time in freely moving rats.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12165169     DOI: 10.1089/152091502760098447

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  2 in total

1.  Recent advances in continuous glucose monitoring: biocompatibility of glucose sensors for implantation in subcutis.

Authors:  Peter H Kvist; Henrik E Jensen
Journal:  J Diabetes Sci Technol       Date:  2007-09

2.  Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis.

Authors:  Eleonora Malerba; Chiara Cattani; Francesca Del Baldo; Gaia Carotenuto; Sara Corradini; Stefania Golinelli; Ignazio Drudi; Federico Fracassi
Journal:  J Vet Intern Med       Date:  2019-11-14       Impact factor: 3.333

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.