Comparison of glucose concentrations in blood samples obtained with a marginal ear vein nick technique versus from a peripheral vein in healthy cats and cats with diabetes mellitus.

Melanie D Thompson1, Susan M Taylor, Vicki J Adams, Cheryl L Waldner, Edward C Feldman.   

Abstract

OBJECTIVE: To compare blood glucose (BG) concentrations measured with a portable blood glucose meter in blood samples obtained with a marginal ear vein (MEV) nick technique, from a peripheral venous catheter, and by direct venipuncture in healthy cats and cats with diabetes mellitus.
DESIGN: Prospective study. ANIMALS: 1 0 healthy cats and 11 cats with diabetes mellitus. Procedure-On day 1, blood samples were collected every hour for 10 hours by the MEV nick technique and from a peripheral venous catheter. On day 2, blood samples were collected every hour for 10 hours by the MEV nick technique and by direct venipuncture of the medial saphenous vein.
RESULTS: For all cats, mean BG concentration for samples collected by the MEV nick technique was not significantly different from mean concentration for samples obtained from the peripheral venous catheter. For healthy cats, mean BG concentration for samples collected by the MEV nick technique was not significantly different from mean concentration for samples obtained by direct venipuncture. For cats with diabetes mellitus, mean BG concentration for samples collected by the MEV nick technique was significantly different from mean concentration for samples obtained by direct venipuncture; however, for the range of concentrations examined, this difference was not clinically important. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that for the range of concentrations examined, the MEV nick technique is a reasonable alternative to venous blood collection for serial measurement of BG concentrations in cats.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12164536     DOI: 10.2460/javma.2002.221.389

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  3 in total

1.  Retrospective study of owners' perception on home monitoring of blood glucose in diabetic dogs and cats.

Authors:  I Van de Maele; N Rogier; S Daminet
Journal:  Can Vet J       Date:  2005-08       Impact factor: 1.008

Review 2.  Monitoring methods for dogs and cats with diabetes mellitus.

Authors:  Audrey K Cook
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

3.  Comparison of a human portable blood glucose meter and automated chemistry analyser for measurement of blood glucose concentrations in healthy dogs.

Authors:  Sihem Ismail-Hamdi; Mohamed Néjib Romdane; Samir Ben Romdhane
Journal:  Vet Med Sci       Date:  2021-08-05
  3 in total