Experience with a dual chamber implantable defibrillator.

Volker Kühlkamp1, Bruce L Wilkoff, Amy B Brown, Kent J Volosin, B J Hügl, Wayne Stafford, Douglas A Cameron.   

Abstract

An implantable defibrillator with dual chamber pacing may have advantages for pacing, sensing, and detection of brady- and tachyarrhythmias. This study evaluates the safety and performance of a dual chamber implantable cardioverter defibrillator that incorporates an algorithm to discriminate supraventricular from ventricular arrhythmias. The 300 patients in this study had the device implanted for the following indications: ventricular tachycardia (47%), sudden cardiac death survivorship (51%), and prophylactic implants (2%). Patients received dual chamber pacing for accepted bradyarrhythmic (51.7%) or investigational indications. During a mean follow-up period of 1.7 months a total of 1,092 arrhythmia episodes in 96 patients were fully documented in the device memory: 66 patients experienced a total of 796 ventricular tachyarrhythmia episodes and 42 experienced a total of 296 supraventricular episodes. The device appropriately detected 100% of sustained ventricular tachyarrhythmias while reducing the inappropriate detection of supraventricular tachyarrhythmias by 72% compared to single chamber rate only detection. The positive predictive value was 90.5% for ventricular tachyarrhythmia detection in episodes that exceeded the tachycardia detection rate. Adverse events observed in at least 2% of the patients were incisional pain (22%), inappropriate ventricular detection (7%), atrial lead dislodgement (4%), atrial oversensing/undersensing (3%), hematoma (3%), incessant ventricular tachyarrhythmia (2%), and pneumothorax (2%). There were 13 deaths, none of which were attributed to device failure. The Gem DR is safe and effective for the detection and treatment of ventricular tachyarrhythmias. The dual chamber detection algorithm appropriately recognized supraventricular tachycardia with rapid ventricular rates 72% of the time while maintaining 100% detection of sustained ventricular tachyarrhythmias.

Entities:  

Mesh:

Year:  2002        PMID: 12164444     DOI: 10.1046/j.1460-9592.2002.01041.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Single-brand dual-chamber discriminators to prevent inappropriate shocks in patients implanted with prophylactic implantable cardioverter defibrillators: a propensity-weighted comparison of single- and dual-chamber devices.

Authors:  Sem Briongos-Figuero; Ana Sánchez; M Luisa Pérez; José B Martínez-Ferrer; Enrique García; Xavier Viñolas; Ángel Arenal; Javier Alzueta; Nuria Basterra; Aníbal Rodríguez; Ignacio Lozano; Roberto Muñoz-Aguilera
Journal:  J Interv Card Electrophysiol       Date:  2018-12-06       Impact factor: 1.900

2.  Standardized programming to reduce the burden of inappropriate therapies in implantable cardioverter defibrillators - Single centre follow up results.

Authors:  U Boles; E E Gul; L Fitzgerald; F Sadiq Ali; C Nolan; K Aldworth-Gaumond; D R Redfearn; A Baranchuk; B Glover; C Simpson; H Abdollah; K A Michael
Journal:  Indian Pacing Electrophysiol J       Date:  2017-10-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.