| Literature DB >> 12162708 |
Advait V Badkar1, Ajay K Banga.
Abstract
The purpose of this study was to establish the delivery parameters for the enhanced transdermal delivery of dextran sulfate (MW 5000 Da). Full-thickness pig skin or epidermis separated from human cadaver skin was used. Silver-silver chloride electrodes were used to deliver the current (0.5 mA cm-2). For electroporation experiments, one or more pulses were given using an exponential decay pulse generator. The correct polarity for iontophoresis and pulsing was first established as cathode in the donor. The amount of drug delivered increased with increasing donor concentration up to a point, but not any further. The amount delivered also increased with pulse voltage, the delivery being twice as much as with iontophoresis alone (144.5+/-10.35 microg cm(-2)), when 6 pulses of 500 V were applied at time zero before iontophoresis (276+/-45.2 microg cm(-2)). It was observed that the amount delivered was a function of increasing pulse length when the apparent charge delivered was kept constant. Transport through pig skin (107.4+/-24.4 microg cm(-2)) was found to be comparable with that through human epidermis (84.9+/-18.4 microg cm(-2)). In conclusion, we have demonstrated the transdermal delivery of a 5000 Da molecular weight dextran sulfate using iontophoresis. It was also seen that iontophoretic delivery could be enhanced by simultaneous electroporation.Entities:
Mesh:
Substances:
Year: 2002 PMID: 12162708 DOI: 10.1211/002235702760089018
Source DB: PubMed Journal: J Pharm Pharmacol ISSN: 0022-3573 Impact factor: 3.765