Literature DB >> 12153791

Elapsed time for capsular apposition to intraocular lens after cataract surgery.

Hideyuki Hayashi1, Ken Hayashi, Fuminori Nakao, Fumihiko Hayashi.   

Abstract

OBJECTIVE: To examine when the anterior and posterior lens capsule completely become apposed to optics of silicone and acrylic intraocular lenses (IOLs) implanted after cataract surgery and to determine whether the different IOL materials influence the timing of completion of capsular contact.
DESIGN: Randomized controlled clinical trial. PARTICIPANTS: Seventy eyes of 70 patients who were scheduled to undergo cataract surgery were randomly assigned to two groups using random number tables based on the type of IOL implanted: silicone or acrylic. Thirty-two patients in each group completed the follow-up. INTERVENTION: All eyes underwent phacoemulsification surgery with implantation of either a silicone or acrylic IOL. All IOLs were accurately placed into the capsular bag. MAIN OUTCOME MEASURES: Contact of the anterior and posterior lens capsule with the IOL optic surface was evaluated using the Scheimpflug videophotography system at 3, 5, 7, 9, 11, 14, 21, and 28 days after surgery. The postoperative day at which each capsule was completely apposed to the IOL optic was determined. In addition, anterior chamber depth was also measured.
RESULTS: The anterior capsule was in contact with the IOL optic on the same day or earlier than the posterior capsule in all patients. Complete apposition of the IOL was observed significantly earlier with silicone IOLs than with acrylic IOLs with both the anterior capsule (6.2 versus 3.6 postoperative days; P < 0.0001) and the posterior capsule (11.1 versus 7.4 postoperative days; P = 0.0339). No significant change in mean anterior chamber depth was observed with the silicone IOL, whereas there was significant anterior shift after implantation of the acrylic IOL.
CONCLUSIONS: Capsular contact with the IOL optic is completed within approximately 8 days after cataract surgery with silicone IOLs and 11 days with acrylic IOLs. Complete apposition to both the anterior and posterior capsule was significantly earlier with silicone IOLs than with acrylic IOLs.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12153791     DOI: 10.1016/s0161-6420(02)01112-0

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  8 in total

1.  Single versus three piece acrylic IOLs.

Authors:  D F Chang
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

2.  Effect of delivery of MMP inhibitors from PDMS as a model IOL material on PCO markers.

Authors:  Diana Morarescu; Judy A West-Mays; Heather D Sheardown
Journal:  Biomaterials       Date:  2009-12-22       Impact factor: 12.479

3.  Three-dimensional assessment of posterior capsule-intraocular lens interaction with and without primary posterior capsulorrhexis: an intraindividual randomized trial.

Authors:  Mengting Yu; Yue Huang; Yingbin Wang; Suzhen Xiao; Xinna Wu; Wenjie Wu
Journal:  Eye (Lond)       Date:  2021-10-23       Impact factor: 4.456

4.  In vitro growth of lens epithelial cells from cataract patients - association with possible risk factors for posterior capsule opacification.

Authors:  Karin Sundelin; Anne Petersen; Yalda Soltanpour; Madeleine Zetterberg
Journal:  Open Ophthalmol J       Date:  2014-05-30

5.  Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification.

Authors:  Ritu Nagpal; Chetan Shakkarwal; Rinky Agarwal; Rahul Kumar Bafna; Prafulla Kumar Maharana; Namrata Sharma
Journal:  Clin Ophthalmol       Date:  2021-05-10

6.  Altered stress field of the human lens capsule after cataract surgery.

Authors:  Caleb C Berggren; Kurt A Ameku; Ryan M Pedrigi
Journal:  J Biomech       Date:  2020-11-10       Impact factor: 2.712

7.  An Optical Section-Assisted In Vivo Rabbit Model for Capsular Bend and Posterior Capsule Opacification Investigation.

Authors:  Pingjun Chang; Lei Lin; Qian Zheng; Fang Yu; Xiaoyu Yu; Yinying Zhao; Xixia Ding; Weigen Zhu; Jin Li; Yun-E Zhao
Journal:  PLoS One       Date:  2016-02-03       Impact factor: 3.240

8.  The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography.

Authors:  Xixia Ding; Qinmei Wang; Pingjun Chang; Jin Li; Giacomo Savini; Jinhai Huang; Shenghai Huang; Yinying Zhao; Na Liao; Lei Lin; Xiaoyu Yu; Yun-e Zhao
Journal:  PLoS One       Date:  2015-11-23       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.