Literature DB >> 12153448

Radiological examination of dental castings -- a review of the method and comparisons of the equipment.

Michael Eisenburger1, Martin Addy.   

Abstract

The mechanical stability of crowns or bridges as well as frameworks for removable partial dentures depends on factors like thickness and metal structure. The biological compatibility can be influenced by porosities and soldered joints. Radiological testing is a non-destructive method to check defects in dental castings. As dental precious metal alloys have high X-ray absorption, testing of high gold alloys should be performed with a suitable X-ray machine at a tube voltage of 120 kV since the X-ray penetration of dental X-ray units using a tube voltage of 70 to 80 kV is not high enough for these alloys. As the absorption of Co-Cr alloys and of titanium is much lower, these materials can be tested with a dental X-ray apparatus. The radiographs show location and size of metal defects. They enable an examination of metal thickness and content of porosities. Metal defects reducing the biological compatibility or cast stability can be detected prior to clinical fitting.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12153448     DOI: 10.1046/j.1365-2842.2002.00938.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  4 in total

1.  Customised attachments retained cheek plumper prosthesis: a case report.

Authors:  Nandita N Keni; Meena A Aras; Vidya Chitre
Journal:  J Indian Prosthodont Soc       Date:  2012-06-08

Review 2.  Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature.

Authors:  Youssef S Al Jabbari
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

3.  Comparative study of two commercially pure titanium casting methods.

Authors:  Renata Cristina Silveira Rodrigues; Adriana Claudia Lapria Faria; Iara Augusta Orsi; Maria da Gloria Chiarello de Mattos; Ana Paula Macedo; Ricardo Faria Ribeiro
Journal:  J Appl Oral Sci       Date:  2010 Sep-Oct       Impact factor: 2.698

4.  Microstructures and Mechanical Properties of Co-Cr Dental Alloys Fabricated by Three CAD/CAM-Based Processing Techniques.

Authors:  Hae Ri Kim; Seong-Ho Jang; Young Kyung Kim; Jun Sik Son; Bong Ki Min; Kyo-Han Kim; Tae-Yub Kwon
Journal:  Materials (Basel)       Date:  2016-07-20       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.