Literature DB >> 12147845

Painful infection at the site of hip prosthesis: CT imaging.

Catherine Cyteval1, Vivien Hamm, M Pierre Sarrabère, F Michel Lopez, Philippe Maury, Patrice Taourel.   

Abstract

PURPOSE: To prospectively determine the accuracy of computed tomography (CT) in the detection of painful infection at the site of hip prosthesis before surgery.
MATERIALS AND METHODS: Helical CT examinations of hip prostheses were prospectively performed before surgery after a standard clinical and radiologic examination of 65 patients. CT scans and conventional radiographs were reviewed for periprosthetic bone abnormalities, and CT scans were reviewed for periprosthetic soft-tissue abnormalities (joint distention, fluid-filled bursae, and fluid collection in muscles and perimuscular fat). Patients subsequently underwent revision arthroplasty within 1 month, and infection was diagnosed in 12 (19%) patients.
RESULTS: Infection was detected clinically in 25% of patients. Periprosthetic bone abnormalities did not allow differentiation of infection from complications not related to sepsis, except for periostitis, with 100% specificity but only 16% sensitivity. Soft-tissue findings were accurate for detection of infection, with 100% sensitivity and 87% specificity. Fluid collection in muscles and perimuscular fat had a 100% positive predictive value, and absence of joint distention had a 96% negative predictive value.
CONCLUSION: CT is accurate in the diagnosis of painful infection at the site of a hip prosthesis on the basis of soft-tissue findings, whereas periprosthetic bone abnormalities are not useful. Copyright RSNA, 2002

Entities:  

Mesh:

Year:  2002        PMID: 12147845     DOI: 10.1148/radiol.2242010989

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  20 in total

Review 1.  Diagnostic parameters in periprosthetic infections: the current state of the literature.

Authors:  G Mattiassich; R Ortmaier; F Rittenschober; J Hochreiter
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-06-15

2.  Sonographic assessment of orthopedic hardware impingement on soft tissues of the limbs.

Authors:  R Guillin; S Bianchi
Journal:  J Ultrasound       Date:  2012-01-23

3.  Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty.

Authors:  Xavier Tomas; Guillem Bori; Sebastián Garcia; Ana Isabel Garcia-Diez; Jaime Pomes; Alex Soriano; Jose Ríos; Manel Almela; Josep Mensa; Xavier Gallart; Juan Carlos Martinez; Josep Riba
Journal:  Skeletal Radiol       Date:  2010-05-08       Impact factor: 2.199

4.  Value of multidetector computed tomography for the differentiation of delayed aseptic and septic complications after total hip arthroplasty.

Authors:  Jaime Isern-Kebschull; Xavier Tomas; Ana Isabel García-Díez; Laura Morata; Ignacio Moya; José Ríos; Alex Soriano
Journal:  Skeletal Radiol       Date:  2020-01-03       Impact factor: 2.199

5.  Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid.

Authors:  Mehrsima Abdoli; Johan R de Jong; Jan Pruim; Rudi A J O Dierckx; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-18       Impact factor: 9.236

Review 6.  Bone scan usefulness in patients with painful hip or knee prosthesis: 10 situations that can cause pain, other than loosening and infection.

Authors:  Sofia Vaz; Teresa C Ferreira; Lucília Salgado; Frédéric Paycha
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-11-30

7.  Focal osteolysis in total hip replacement: CT findings.

Authors:  Ji Seon Park; Kyung Nam Ryu; Hoon Pyo Hong; Yong Koo Park; Young Soo Chun; Myung Chul Yoo
Journal:  Skeletal Radiol       Date:  2004-07-31       Impact factor: 2.199

Review 8.  Surgical site infections in older adults: epidemiology and management strategies.

Authors:  Michael H Young; Laraine Washer; Preeti N Malani
Journal:  Drugs Aging       Date:  2008       Impact factor: 3.923

9.  [CT and MRI of hip arthroplasty].

Authors:  C A Agten; R Sutter; C W A Pfirrmann
Journal:  Radiologe       Date:  2014-07       Impact factor: 0.635

Review 10.  Prosthetic joint infection.

Authors:  Aaron J Tande; Robin Patel
Journal:  Clin Microbiol Rev       Date:  2014-04       Impact factor: 26.132

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.