Literature DB >> 12146631

The use of inert carriers in regulatory biodegradation tests of low density poorly water-soluble substances.

J W Handley1, C Mead, G A Rausina, L J Waid, J C Gee, S J Herron.   

Abstract

Many poorly water-soluble compounds fail regulatory ready biodegradation tests as the method of test material preparation limits the bioavailability of the chemical. The recognised method for delivery of poorly soluble materials into biodegradability tests consists of coating test material inside the test vessel or onto inert substrates (i.e., glass cover slide, boiling beads, filter paper, or Teflon stir bar) that are placed inside the vessels. Volatile solvents are often used to augment this process. Although these substrates work fairly well for delivering many poorly soluble materials into biodegradability tests, they have not been effective in keeping low density, poorly water-soluble substances in the test medium. Soon after medium is added to the test vessels, these chemicals break loose from the substrates and float on the surface where they have limited contact with micro-organisms in the test medium. Hence, there is a reduced potential for measuring substantial biodegradability in the test. This paper describes the work undertaken to establish a standard method of adding low density, poorly water-soluble substances into test vessels of biodegradability studies to ensure these materials remain in contact with micro-organisms in the test medium. The substances are prepared for testing by adsorption onto silica gel followed by dispersion into the culture medium. This method of delivery may provide greater intra- and inter-laboratory consistency in biodegradability test results for low density, poorly water-soluble substances and it may more closely mimic the probable transport and fate of these substances in the environment.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12146631     DOI: 10.1016/s0045-6535(02)00132-7

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  1 in total

1.  Evaluating the ready biodegradability of two poorly water-soluble substances: comparative approach of bioavailability improvement methods (BIMs).

Authors:  Cyril Sweetlove; Jean-Charles Chenèble; Yves Barthel; Marc Boualam; Jacques L'Haridon; Gérald Thouand
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-28       Impact factor: 4.223

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.