A practical demonstration of improved technique factors in paediatric fluoroscopy.

J W Fenner1, G D Morrison, J Kerry, N West.   

Abstract

Dose incurred with fluoroscopic procedures accounts for a significant proportion of medically induced diagnostic exposure. Children are particularly vulnerable and it is therefore important to minimize exposure where practicable. A recent theoretical study has highlighted the potential for X-ray equipment to produce significant dose savings during paediatric fluoroscopy without incurring loss of diagnostic image quality. This is achieved by hardening the beam with additional copper (Cu) filtration (approximately 0.2 mm Cu) and biasing exposure factors towards low tube potential, high tube current output. In practice, this method will have limited applicability because the high powered and programmable generator characteristics required are not commonly available in installations used for paediatric imaging. However, we describe a simple experiment in which our clinical equipment was modified to approximate desired low dose performance by altering the filtration and automatic exposure control characteristics of ordinary clinical equipment in the Sheffield Children's Hospital. This enabled us to obtain significant savings in dose. We performed a comparative study (normal dose vs low dose) using water phantoms to simulate patient attenuation in the age range 0-15 years. The Leeds N2 contrast sensitivity phantom was used to provide a measure of image quality. Dosimetric measurements recorded up to 40% reduction in dose rate with only marginal loss of image quality when 0.1-0.2 mm Cu filtration was used with the modified settings. This is a strong indication that significant dose reduction is achievable on routine clinical equipment without compromising image quality. Such simple and cost effective methods of dose reduction should be considered for wider implementation.

Entities:  

Mesh:

Year:  2002        PMID: 12145133     DOI: 10.1259/bjr.75.895.750596

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  Optimization and audit of radiation dose during percutaneous transluminal coronary angioplasty.

Authors:  Roshan S Livingstone; B S Timothy Peace; Sunil Chandy; Paul V George; Purendra Pati
Journal:  J Med Phys       Date:  2007-10

2.  Initial quality performance results using a phantom to simulate chest computed radiography.

Authors:  Wilbroad Muhogora; Renato Padovani; Peter Msaki
Journal:  J Med Phys       Date:  2011-01

3.  Optimisation in fluoroscopy.

Authors:  B Axelsson
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

4.  Patient radiation exposure during general fluoroscopy examinations.

Authors:  Jeska S Wambani; Geoffrey K Korir; Mark A Tries; Ian K Korir; Jedidah M Sakwa
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.