Literature DB >> 12141684

Sonic spray ionization technology: performance study and application to a LC/MS analysis on a monolithic silica column for heroin impurity profiling.

Riet Dams1, Tom Benijts, Wolfgang Günther, Willy Lambert, André De Leenheer.   

Abstract

Sonic spray (SS) ionization is a relatively novel atmospheric pressure ionization technique for LC/MS, based on the principle of "spray ionization", which only recently became commercially available. In this paper, we evaluate the performance of this ion source as an interface for LC/MS in comparison with the more traditional and better studied pneumatically assisted electrospray or ion spray (IS). The effect of organic modifiers, volatile acids, and buffer systems in the LC eluent on the ionization efficiency of both interfaces is described and some possible explanations for the observed phenomena are highlighted. We could conclude that the presence of organic solvents gradually increased the ionization efficiency for IS and SS, while volatile acids or buffers gave a significant signal suppression. Furthermore, we present the application of the sonic spray interface to a fast LC/MS analysis, for the simultaneous determination of the seven prime opium alkaloids in heroin impurity profiling. Chromatographic separation is performed in 5 min on a monolithic silica column (Chromolith Performance) with a gradient elution system and an optimized flow of 5 mL/min. By means of a postcolumn split of approximately 1/20, a coupling between the fast LC system and the mass spectrometer is made. The method is validated and successfully applied to the analysis of real-time seized heroin street samples.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12141684     DOI: 10.1021/ac0112824

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Ultrasonication-assisted spray ionization mass spectrometry for the analysis of biomolecules in solution.

Authors:  Tsung-Yi Chen; Jia-Yi Lin; Jen-Yi Chen; Yu-Chie Chen
Journal:  J Am Soc Mass Spectrom       Date:  2010-05-06       Impact factor: 3.109

2.  Bipolar mass spectrometry of labile coordination complexes, redox active inorganic compounds, and proteins using a glass nebulizer for sonic-spray ionization.

Authors:  Manolis M Antonakis; Alexandra Tsirigotaki; Katerina Kanaki; Constantinos J Milios; Spiros A Pergantis
Journal:  J Am Soc Mass Spectrom       Date:  2013-06-13       Impact factor: 3.109

3.  Simultaneous liquid chromatography-mass spectrometry quantification of urinary opiates, cocaine, and metabolites in opiate-dependent pregnant women in methadone-maintenance treatment.

Authors:  Diaa M Shakleya; Riet Dams; Robin E Choo; Hendree Jones; Marilyn A Huestis
Journal:  J Anal Toxicol       Date:  2010 Jan-Feb       Impact factor: 3.367

4.  Automatic sampling and analysis of organics and biomolecules by capillary action-supported contactless atmospheric pressure ionization mass spectrometry.

Authors:  Cheng-Huan Hsieh; Anil Kumar Meher; Yu-Chie Chen
Journal:  PLoS One       Date:  2013-06-06       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.