Literature DB >> 12141657

Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection.

Julia Yakovleva1, Richard Davidsson, Anna Lobanova, Martin Bengtsson, Sergei Eremin, Thomas Laurell, Jenny Emnéus.   

Abstract

Silicon microchips with immobilized antibodies were used to develop microfluidic enzyme immunoassays using chemiluminescence detection and horseradish peroxidase (HRP) as the enzyme label. Polyclonal anti-atrazine antibodies were coupled to the silicon microchip surface with an overall dimension of 13.1 x 3.2 mm, comprising 42 porous flow channels of 235-microm depth and 25-microm width. Different immobilization protocols based on covalent or noncovalent modification of the silica surface with 3-aminopropyltriethoxysilane (APTES) or 3-glycidoxypropyltrimethoxysilane (GOPS), linear polyethylenimine (LPEI, MW 750,000), or branched polyethylenimine (BPEI, MW 25,000), followed by adsorption or covalent attachment of the antibody, were evaluated to reach the best reusability, stability, and sensitivity of the microfluidic enzyme immunoassay (microFEIA). Adsorption of antibodies on a LPEI-modified silica surface and covalent attachment to physically adsorbed BPEI lead to unstable antibody coatings. Covalent coupling of antibodies via glutaraldehyde (GA) to three different functionalized silica surfaces (APTES-GA, LPEI-GA, and GOPS-BPEI-GA) resulted in antibody coatings that could be completely regenerated using 0.4 M glycine/HCl, pH 2.2. The buffer composition was shown to have a dramatic effect on the assay stability, where the commonly used phosphate buffer saline was proved to be the least suitable choice. The best long-term stability was obtained for the LPEI-GA surface with no loss of antibody activity during one month. The detection limits in the microFEIA for the three different immuno surfaces were 45, 3.8, and 0.80 ng/L (209, 17.7, and 3.7 pM) for APTES-GA, LPEI-GA, and GOPS-BPEI-GA, respectively.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12141657     DOI: 10.1021/ac015645b

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  25 in total

1.  Pheromone synthesis in a biomicroreactor coated with anti-adsorption polyelectrolyte multilayer.

Authors:  Nikolay Dimov; Lourdes Muñoz; Gerard Carot-Sans; Michel L P M Verhoeven; Wojciech P Bula; Gülistan Kocer; Angel Guerrero; Han J G E Gardeniers
Journal:  Biomicrofluidics       Date:  2011-07-19       Impact factor: 2.800

2.  Photodeposition of silver can result in metal-enhanced fluorescence.

Authors:  Chris D Geddes; Alexandr Parfenov; Joseph R Lakowicz
Journal:  Appl Spectrosc       Date:  2003-05       Impact factor: 2.388

3.  Enhanced Fluorescence from Fluorophores on Fractal Silver Surfaces.

Authors:  Alexandr Parfenov; Ignacy Gryczynski; Joanna Malicka; Chris D Geddes; Joseph R Lakowicz
Journal:  J Phys Chem B       Date:  2003       Impact factor: 2.991

4.  Electrochemical and Laser Deposition of Silver for Use in Metal-Enhanced Fluorescence.

Authors:  Chris D Geddes; Alexandr Parfenov; David Roll; Jiyu Fang; Joseph R Lakowicz
Journal:  Langmuir       Date:  2003-07-22       Impact factor: 3.882

Review 5.  Protein immobilization techniques for microfluidic assays.

Authors:  Dohyun Kim; Amy E Herr
Journal:  Biomicrofluidics       Date:  2013-07-30       Impact factor: 2.800

Review 6.  Recent Advances on Luminescent Enhancement-Based Porous Silicon Biosensors.

Authors:  S N Aisyiyah Jenie; Sally E Plush; Nicolas H Voelcker
Journal:  Pharm Res       Date:  2016-02-25       Impact factor: 4.200

Review 7.  Emerging protein array technologies for proteomics.

Authors:  Jung-Rok Lee; Dewey Mitchell Magee; Richard Samuel Gaster; Joshua LaBaer; Shan X Wang
Journal:  Expert Rev Proteomics       Date:  2013-02       Impact factor: 3.940

8.  Application of physicochemically modified silicon substrates as reverse-phase protein microarrays.

Authors:  A Jasper Nijdam; Michael R Zianni; Edward E Herderick; Mark M-C Cheng; Jenifer R Prosperi; Fredika A Robertson; Emanuel F Petricoin; Lance A Liotta; Mauro Ferrari
Journal:  J Proteome Res       Date:  2009-03       Impact factor: 4.466

9.  Rapid quantification of disease-marker proteins using continuous-flow immunoseparation in a nanosieve fluidic device.

Authors:  Masumi Yamada; Pan Mao; Jianping Fu; Jongyoon Han
Journal:  Anal Chem       Date:  2009-08-15       Impact factor: 6.986

10.  On-chip microfluidic systems for determination of L-glutamate based on enzymatic recycling of substrate.

Authors:  W Laiwattanapaisal; J Yakovleva; M Bengtsson; T Laurell; S Wiyakrutta; V Meevootisom; O Chailapakul; J Emnéus
Journal:  Biomicrofluidics       Date:  2009-03-16       Impact factor: 2.800

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.