Literature DB >> 12141544

Multicomponent analysis of volatile organic compounds in water by automated purge and trap coupled to gas chromatography-mass spectrometry.

Elena Martínez1, Sílvia Lacorte, Isabel Llobet, Paula Viana, Damià Barceló.   

Abstract

The performance of an automated purge and trap concentrator coupled to gas chromatography-mass spectrometric detection was evaluated by analyzing 40 volatile organic compounds of different chemical families. Compounds chosen defined as toxic for the environment and for human health were selected according to Directive 76/464/CEE. The present work includes: (i) the optimization of the purge and trap conditions, (ii) the establishment of quality parameters and in last instance (iii) the analysis of surface waters. The analytical method consisted of a modification of the EPA Method 524.2 in which water was pumped, via an automated AquaTek 70 Liquid Autosampler to a 25-ml purging device, where samples were purged and trapped in a Tenax or Tenax-Silica and Charcoal column. Afterwards, helium was used to desorb the trapped analytes that flow directly into the GC column. Mass spectrometric analysis was carried out in selected ion monitoring and scan modes to ensure quantification and confirmation of the results. Parameters optimized were the sample volume analyzed, bubbling flow-rate and time and temperature of desorption. Optimal conditions lead to mean recoveries of 80%, limits of detection between 0.002 and 0.1 microg/l, linearity from 0.01 to 2.5 microg/l and maximum standard deviation of 10%, using a Tenax trap. This protocol permitted a high precision and sample throughput and was used to determine volatile organic compounds in surface river, effluents and coastal waters of Portugal, on a routine basis.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12141544     DOI: 10.1016/s0021-9673(02)00439-9

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Determination of chlorinated solvents in industrial water and wastewater by DAI-GC-ECD.

Authors:  Marek Tobiszewski; Jacek Namieśnik
Journal:  Anal Bioanal Chem       Date:  2011-01-29       Impact factor: 4.142

2.  High-sensitivity infrared attenuated total reflectance sensors for in situ multicomponent detection of volatile organic compounds in water.

Authors:  Rui Lu; Wen-Wei Li; Boris Mizaikoff; Abraham Katzir; Yosef Raichlin; Guo-Ping Sheng; Han-Qing Yu
Journal:  Nat Protoc       Date:  2016-01-28       Impact factor: 13.491

3.  Comprehensive screening and priority ranking of volatile organic compounds in Daliao River, China.

Authors:  Huilian Ma; Haijun Zhang; Longxing Wang; Jincheng Wang; Jiping Chen
Journal:  Environ Monit Assess       Date:  2014-01-05       Impact factor: 2.513

4.  Toward the Required Detection Limits for Volatile Organic Constituents in Marine Environments with Infrared Evanescent Field Chemical Sensors.

Authors:  Carina Dettenrieder; Yosef Raichlin; Abraham Katzir; Boris Mizaikoff
Journal:  Sensors (Basel)       Date:  2019-08-21       Impact factor: 3.576

5.  Determination of chlorinated hydrocarbons in water using highly sensitive mid-infrared sensor technology.

Authors:  Rui Lu; Boris Mizaikoff; Wen-Wei Li; Chen Qian; Abraham Katzir; Yosef Raichlin; Guo-Ping Sheng; Han-Qing Yu
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

6.  Automatic On-Line Purge-and-Trap Sequential Injection Analysis for Trace Ammonium Determination in Untreated Estuarine and Seawater Samples.

Authors:  Athina Dimitriadou; Aristidis Anthemidis
Journal:  Molecules       Date:  2020-03-29       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.