Literature DB >> 12141355

Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study.

Emmanuel Bossy1, Maryline Talmant, Pascal Laugier.   

Abstract

In recent years, quantitative ultrasound (QUS) has played an increasing role in the assessment of bone status. The axial transmission technique allows to investigate skeletal sites such as the cortical layer of long bones (radius, tibia), inadequate to through-transmission techniques. Nevertheless, the type of propagation involved along bone specimens has not been clearly elucidated. Axial transmission is investigated here by means of two-dimensional simulations at 1 MHz. We focus our interest on the apparent speed of sound (SOS) of the first arriving signal (FAS). Its dependence on the thickness of the plate is discussed and compared to previous work. Different time criteria are used to derive the apparent SOS of the FAS as a function of source-receiver distance. Frequency-wave number analysis is performed in order to understand the type of propagation involved. For thick plates (thickness>lambdabone, longitudinal wavelength in bone), and for a limited range of source-receiver distances, the FAS corresponds to the lateral wave. Its velocity equals the longitudinal bulk velocity of the bone. For plate thickness less than lambdabone, some plate modes contribute to the FAS, and the apparent SOS decreases with the thickness in a way that depends on both the time criterion and on the source-receiver distance. The FAS corresponds neither to the lateral wave nor to a single plate mode. For very thin plates (thickness< lambdabone/4), the apparent SOS tends towards the velocity of the lowest order symmetrical vibration mode (S0 Lamb mode).

Mesh:

Year:  2002        PMID: 12141355     DOI: 10.1121/1.1480836

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  18 in total

1.  Assessment of the tibia using ultrasonic guided waves in pubertal girls.

Authors:  P Moilanen; P H F Nicholson; T Kärkkäinen; Q Wang; J Timonen; S Cheng
Journal:  Osteoporos Int       Date:  2003-10-15       Impact factor: 4.507

2.  Low-frequency axial ultrasound velocity correlates with bone mineral density and cortical thickness in the radius and tibia in pre- and postmenopausal women.

Authors:  V Kilappa; P Moilanen; L Xu; P H F Nicholson; J Timonen; S Cheng
Journal:  Osteoporos Int       Date:  2010-06-25       Impact factor: 4.507

3.  Use of multiple acoustic wave modes for assessment of long bones: model study.

Authors:  Alexey Tatarinov; Noune Sarvazyan; Armen Sarvazyan
Journal:  Ultrasonics       Date:  2005-03-31       Impact factor: 2.890

Review 4.  Topography of acoustical properties of long bones: from biomechanical studies to bone health assessment.

Authors:  Alexey Tatarinov; Armen Sarvazyan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

5.  Quantitative ultrasound measurement of bone density based on dynamic time window: suitable for the measurement of speed of sound in radius.

Authors:  Yang Xu; Yubing Xu; Yanyan Chen; Zenghui Ding; Zuchang Ma; Yining Sun
Journal:  J Med Ultrason (2001)       Date:  2016-04-20       Impact factor: 1.314

6.  Artificial neural network to estimate micro-architectural properties of cortical bone using ultrasonic attenuation: A 2-D numerical study.

Authors:  Kaustav Mohanty; Omid Yousefian; Yasamin Karbalaeisadegh; Micah Ulrich; Quentin Grimal; Marie Muller
Journal:  Comput Biol Med       Date:  2019-09-20       Impact factor: 4.589

7.  Discrimination of fractures by low-frequency axial transmission ultrasound in postmenopausal females.

Authors:  P Moilanen; M Määttä; V Kilappa; L Xu; P H F Nicholson; M Alén; J Timonen; T Jämsä; S Cheng
Journal:  Osteoporos Int       Date:  2012-05-26       Impact factor: 4.507

Review 8.  Quantitative ultrasound: use in the detection of fractures and in the assessment of bone composition.

Authors:  Claus-C Glüer; Reinhard Barkmann
Journal:  Curr Osteoporos Rep       Date:  2003-12       Impact factor: 5.096

9.  Axial transmission method for long bone fracture evaluation by ultrasonic guided waves: simulation, phantom and in vitro experiments.

Authors:  Kailiang Xu; Dean Ta; Runxin He; Yi-Xian Qin; Weiqi Wang
Journal:  Ultrasound Med Biol       Date:  2014-01-13       Impact factor: 2.998

10.  Quantitative bone US measurements in neonates and their mothers.

Authors:  Winston W K Koo; Monika Bajaj; Mfed Mosely; Mouhanad Hammami
Journal:  Pediatr Radiol       Date:  2008-10-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.