PURPOSE: To evaluate the effect of attempted eyelid closure on intraocular pressure (IOP) measurements in normal-tension (NTG) and high-tension (HTG) open-angle glaucoma patients.
DESIGN: Prospective clinical trial.
METHODS: Forty randomly selected eyes of 40 patients underwent corneal pachymetry and IOP measurements using both Goldmann applanation tonometry and Tono-pen XL (Mentor, Inc., Norwell, Massachusetts, USA). Intraocular pressure was measured by the same examiner holding the eyelids open, both with and without the subject simultaneously attempting forced eyelid closure. Subjects were seated during all measurements and waited 5 minutes between measurements with each instrument; the order of measurement was randomized.
RESULTS: Twenty NTG and 20 HTG eyes were enrolled. The mean age was 63.0 +/- 13.0 years (range, 31-80 years). The average corneal thickness was 540 +/- 32 microm (range, 480-608 microm) in NTG patients and 552 +/- 40 microm (range, 449-610 microm) in HTG patients (P =.07, analysis of variance [ANOVA]). Using Goldmann applanation tonometry, IOP measurement in eyes with NTG increased by 3.9 +/- 2.0 mm Hg with attempted eyelid closure (P <.0001, paired t test; range, 2-11 mm Hg). With the Tono-pen XL, IOP measurements increased 4.2 +/- 2.7 mm Hg (P <.0001, paired t test; range, 1-14 mm Hg). With attempted forced eyelid closure, the Goldmann applanation measurement in eyes with HTG increased 4.1 +/- 2.1 mm Hg (P <.0001, paired t test; range, 1-9 mm Hg). Using the Tono-pen XL, measurements increased 4.5 +/- 2.0 mm Hg (P <.0001, paired t test; range, 2-11 mm Hg).
CONCLUSION: Attempted eyelid closure during tonometry is a significant and common source of error in eyes with glaucoma and may influence the clinical management and decision-making in the treatment of NTG and HTG.

Entities:  

Mesh:

Year:  2002        PMID: 12140024     DOI: 10.1016/s0002-9394(02)01513-1

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  6 in total

1.  Effect of a tight necktie on intraocular pressure.

Authors:  C Teng; R Gurses-Ozden; J M Liebmann; C Tello; R Ritch
Journal:  Br J Ophthalmol       Date:  2003-08       Impact factor: 4.638

2.  Risk of glaucoma among patients with benign essential blepharospasm.

Authors:  Michael S Lee; Andrew R Harrison; Daniel S Grossman; Frank A Sloan
Journal:  Ophthalmic Plast Reconstr Surg       Date:  2010 Nov-Dec       Impact factor: 1.746

3.  Implanted Microsensor Continuous IOP Telemetry Suggests Gaze and Eyelid Closure Effects on IOP-A Preliminary Study.

Authors:  Jacqueline J O N van den Bosch; Vincenzo Pennisi; Azzurra Invernizzi; Kaweh Mansouri; Robert N Weinreb; Hagen Thieme; Michael B Hoffmann; Lars Choritz
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-05-03       Impact factor: 4.799

Review 4.  Real-Time Imaging of Retinal Ganglion Cell Apoptosis.

Authors:  Timothy E Yap; Piero Donna; Melanie T Almonte; Maria Francesca Cordeiro
Journal:  Cells       Date:  2018-06-15       Impact factor: 6.600

5.  Factors associated with fluctuations in repeated measurements of intraocular pressure using the Goldmann applanation tonometer in Japanese patients with primary open-angle glaucoma.

Authors:  Kiyoshi Yaoeda; Atsushi Fukushima; Motohiro Shirakashi; Atsushi Miki; Takeo Fukuchi
Journal:  Clin Ophthalmol       Date:  2018-08-17

6.  Effect of Hemifacial Spasm on Intraocular Pressure Measurement.

Authors:  Erdogan Cicik; Rengin Yildirim; Ceyhun Arici; Funda Dikkaya; Osman Sevki Arslan
Journal:  J Ophthalmol       Date:  2018-02-06       Impact factor: 1.909

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.