Literature DB >> 12139051

Potential analytical applications of interfacing a GC to an FT-ICR MS: fingerprinting complex sample matrixes.

J E Szulejko1, T Solouki.   

Abstract

Details of interfacing a high-pressure gas chromatograph to the internal ion source of a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) are described. We present our preliminary results and potential analytical applications of GC/FT-ICR for analyzing complex biological and environmental sample matrixes, such as petroleum mixtures. Based on GC/FT-ICR data, rapid characterization of various automobile gasoline samples is possible. Comparison between acquired data from the GC/FT-ICR MS (in broadband mode) and a commercial GC quadrupole mass spectrometer (QMS) (over a wide mass range) indicates that sensitivity of the GC/FT-ICR MS is an order of magnitude lower. High mass resolution and mass measurement accuracy of FT-ICR MS can be utilized for unambiguous molecular formula identification of unknown analytes.

Year:  2002        PMID: 12139051     DOI: 10.1021/ac011192z

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  A preconcentrator coupled to a GC/FTMS: advantages of self-chemical ionization, mass measurement accuracy, and high mass resolving power for GC applications.

Authors:  Touradj Solouki; Jan E Szulejko; Justin B Bennett; LeRae B Graham
Journal:  J Am Soc Mass Spectrom       Date:  2004-08       Impact factor: 3.109

2.  Dioxin analysis by gas chromatography-Fourier transform ion cyclotron resonance mass spectrometry (GC-FTICRMS).

Authors:  Vince Y Taguchi; Robert J Nieckarz; Ray E Clement; Stefan Krolik; Robert Williams
Journal:  J Am Soc Mass Spectrom       Date:  2010-08-02       Impact factor: 3.109

3.  Combined use of post-ion mobility/collision-induced dissociation and chemometrics for b fragment ion analysis.

Authors:  Behrooz Zekavat; Mahsan Miladi; Christopher Becker; Sharon M Munisamy; Touradj Solouki
Journal:  J Am Soc Mass Spectrom       Date:  2013-07-09       Impact factor: 3.109

4.  Chemometric data analysis for deconvolution of overlapped ion mobility profiles.

Authors:  Behrooz Zekavat; Touradj Solouki
Journal:  J Am Soc Mass Spectrom       Date:  2012-09-05       Impact factor: 3.109

5.  Increasing Polyaromatic Hydrocarbon (PAH) Molecular Coverage during Fossil Oil Analysis by Combining Gas Chromatography and Atmospheric-Pressure Laser Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS).

Authors:  Paolo Benigni; J Daniel DeBord; Christopher J Thompson; Piero Gardinali; Francisco Fernandez-Lima
Journal:  Energy Fuels       Date:  2015-12-14       Impact factor: 3.605

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.