Literature DB >> 12139047

An international evaluation of holmium oxide solution reference materials for wavelength calibration in molecular absorption spectrophotometry.

John C Travis1, Joanne C Zwinkels, Flora Mercader, Arquímedes Ruíz, Edward A Early, Melody V Smith, Mario Noël, Marissa Maley, Gary W Kramer, Kenneth L Eckerle, David L Duewer.   

Abstract

Commercial spectrophotometers typically use absorption-based wavelength calibration reference materials to provide wavelength accuracy for their applications. Low-mass fractions of holmium oxide (Ho2O3) in dilute acidic aqueous solution and in glass matrixes have been favored for use as wavelength calibration materials on the basis of spectral coverage and absorption band shape. Both aqueous and glass Ho2O3 reference materials are available commercially and through various National Metrology Institutes (NMIs). Three NMIs of the North American Cooperation in Metrology (NORAMET) have evaluated the performance of Ho3-(aq)-based Certified Reference Materials (CRMs) under "routine" operating conditions using commercial instrumentation. The study was not intended to intercompare national wavelength scales but to demonstrate comparability of wavelength measurements among the participants and between two versions of the CRMs. It was also designed to acquire data from a variety of spectrophotometers for use in a NIST study of wavelength assignment algorithms and to provide a basis for a possible reassessment of NIST-certified Ho3+(aq) band locations. The resulting data show a substantial level of agreement among laboratories, instruments, CRM preparations, and peak-location algorithms. At the same time, it is demonstrated that the wavelength comparability of the five participating instruments can actually be improved by calibrating all of the instruments to the consensus Ho3+(aq) band locations. This finding supports the value of absorption-based wavelength standards for calibrating absorption spectrophotometers. Coupled with the demonstrated robustness of the band position values with respect to preparation and measurement conditions, it also supports the concept of extending the present approach to additional NMIs in order to certify properly prepared dilute acidic Ho2O3 solution as an intrinsic wavelength standard.

Entities:  

Year:  2002        PMID: 12139047     DOI: 10.1021/ac0255680

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  How to improve quality assurance in fluorometry: fluorescence-inherent sources of error and suited fluorescence standards.

Authors:  U Resch-Genger; K Hoffmann; W Nietfeld; A Engel; J Neukammer; R Nitschke; B Ebert; R Macdonald
Journal:  J Fluoresc       Date:  2005-05       Impact factor: 2.217

2.  Performance validation for microplate fluorimeters.

Authors:  Robert Giebeler; Evelyn McGown; Todd French; John C Owicki
Journal:  J Fluoresc       Date:  2005-05       Impact factor: 2.217

3.  Eliminating the middleman: ultraviolet scale realization using a laser-driven plasma light source.

Authors:  Uwe Arp; Edward Hagley; Robert Vest
Journal:  Appl Opt       Date:  2021-02-20       Impact factor: 1.980

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.