Automatic mode switching of implantable pacemakers: I. Principles of instrumentation, clinical, and hemodynamic considerations.

Chu-Pak Lau1, Sum-Kin Leung, Hung-Fat Tse, S Serge Barold.   

Abstract

Automatic mode switching (AMS) is now a programmable function in most contemporary dual chamber pacemakers. Atrial tachyarrhythmias are detected when the sensed atrial rate exceeds a "rate-cutoff," "running average," "sensor-based physiological" rate, or using "complex" detection algorithms. AMS algorithms differ in their atrial tachyarrhythmia detection method, sensitivity, and specificity and, thus, respond differently to atrial tachyarrhythmia in terms of speed to the AMS onset, rate stability of the response, and speed to resynchronize to sinus rhythm. AMS is hemodynamically beneficial, and most patients with atrial tachyarrhythmias are symptomatically better with an AMS algorithm in their pacemakers. New diagnostic capabilities of pacemaker especially stored electrograms not only allow programming of the AMS function, but enable quantification of atrial fibrillation burden that facilitate clinical management of patients with implantable devices who have concomitant atrial tachyarrhythmia.

Entities:  

Mesh:

Year:  2002        PMID: 12137350     DOI: 10.1046/j.1460-9592.2002.00967.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

Review 1.  Follow up and optimisation of cardiac pacing.

Authors:  Paul R Roberts
Journal:  Heart       Date:  2005-09       Impact factor: 5.994

2.  Shortening of the sensed AV delay of a dual chamber pacemaker during normal sinus rhythm.

Authors:  S Serge Barold; Chu-Pak Lau; Hung-Fat Tse; Michael Hess
Journal:  J Interv Card Electrophysiol       Date:  2003-08       Impact factor: 1.900

3.  Efficacy of automatic mode switching in DDDR mode pacemakers: the most 2 study.

Authors:  Maurizio Santomauro; Luca Ottaviano; Alessio Borrelli; Gennaro Galasso; Carlo Duilio; Nicola Monteforte; Luigi Padeletti; Annibale Sandro Montenero; Peter Andrew; Massimo Chiariello
Journal:  J Interv Card Electrophysiol       Date:  2008-01-30       Impact factor: 1.900

4.  Automatic mode switching in atrial fibrillation.

Authors:  Giuseppe Stabile; Antonio De Simone; Enrico Romano
Journal:  Indian Pacing Electrophysiol J       Date:  2005-07-01

5.  Enhanced detection of atrial tachyarrhythmias with pacing devices by using more accurate atrial sensing.

Authors:  Sami Pakarinen; Mika Lehto; Jaap Ruiter; Willem G de Voogt
Journal:  J Interv Card Electrophysiol       Date:  2021-10-01       Impact factor: 1.759

  5 in total