Literature DB >> 12136322

Coarctation of the aorta: comparison of aortic dimensions between conventional MR imaging, 3D MR angiography, and conventional angiography.

François Godart1, Gabrielle Labrot, Patrick Devos, Eugène McFadden, Christian Rey, Jean-Paul Beregi.   

Abstract

Magnetic resonance angiography is increasingly used as a non-invasive method in the evaluation of coarctation of the aorta. The aim of this study was to compare aortic dimensions calculated by MR angiography and those obtained by more conventional MR sequences and conventional angiography. Twenty-six consecutive patients with coarctation underwent three-dimensional MR angiography. Two independent observers retrospectively evaluated three aortic segments, site of coarctation, presence of aneurysm and existence of collateral circulation. Three aortic segments were also compared with those obtained on classical MR sequences and conventional angiography. The MR angiography was successfully performed in all showing 1 aneurysm and collateral circulation in 8 patients. Almost perfect intraobserver ( r(2)>0.91) and excellent interobserver ( r(2)>0.80) reliabilities were obtained for each aortic segment no matter which MR sequence was employed. Similarly, mainly excellent ( r(2)>0.80) concordance analysis was observed between MR angiography measurements and those calculated by either spin-echo/gradient-echo sequences or conventional angiography. This study demonstrates that MR angiography is a fast, accurate and reproducible method in the evaluation of coarctation of the aorta. It provides excellent anatomic information and reliably detects collateral vessels. Magnetic resonance angiography could probably replace the conventional angiography and will provide an additional diagnostic value in combination with turbo spin-echo sequence.

Entities:  

Mesh:

Year:  2002        PMID: 12136322     DOI: 10.1007/s00330-001-1260-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  10 in total

1.  Three-Dimensional Rotational Angiography in the Pediatric Cath Lab: Optimizing Aortic Interventions.

Authors:  Anna Stenger; Sven Dittrich; Martin Glöckler
Journal:  Pediatr Cardiol       Date:  2015-12-14       Impact factor: 1.655

Review 2.  Congenital diseases of the thoracic aorta. Role of MRI and MRA.

Authors:  Vincenzo Russo; Matteo Renzulli; Cesare La Palombara; Rossella Fattori
Journal:  Eur Radiol       Date:  2005-10-26       Impact factor: 5.315

3.  Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease.

Authors:  Michael Fenchel; Gerald F Greil; Petros Martirosian; Ulrich Kramer; Fritz Schick; Claus D Claussen; Ludger Sieverding; Stephan Miller
Journal:  Pediatr Radiol       Date:  2006-09-28

4.  Coarctation of the aorta: pre and postoperative evaluation with MRI and MR angiography; correlation with echocardiography and surgery.

Authors:  D Didier; C Saint-Martin; C Lapierre; P T Trindade; N Lahlaidi; J P Vallee; A Kalangos; B Friedli; M Beghetti
Journal:  Int J Cardiovasc Imaging       Date:  2005-11-03       Impact factor: 2.357

5.  Endovascular management of coarctation of the aorta.

Authors:  D R Turner; P A Gaines
Journal:  Semin Intervent Radiol       Date:  2007-06       Impact factor: 1.513

Review 6.  MR imaging of aortic coarctation.

Authors:  F Secchi; A Iozzelli; G D E Papini; A Aliprandi; G Di Leo; F Sardanelli
Journal:  Radiol Med       Date:  2009-05-14       Impact factor: 3.469

7.  Comparison of contrast and noncontrast magnetic resonance angiography for quantitative analysis of thoracic arteries in young patients with congenital heart defects.

Authors:  Alessia Del Pasqua; Silvina Barcudi; Benedetta Leonardi; Domenico Clemente; Mauro Colajacomo; Stephen P Sanders
Journal:  Ann Pediatr Cardiol       Date:  2011-01

8.  Diagnostic Value of Transthoracic Echocardiography in Patients with Coarctation of Aorta: The Chinese Experience in 53 Patients Studied between 2008 and 2012 in One Major Medical Center.

Authors:  Zhenxing Sun; Tsung O Cheng; Ling Li; Li Zhang; Xinfang Wang; Nianguo Dong; Qing Lv; Ke Li; Li Yuan; Jing Wang; Mingxing Xie
Journal:  PLoS One       Date:  2015-06-01       Impact factor: 3.240

Review 9.  SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance.

Authors:  Tim Leiner; Jan Bogaert; Matthias G Friedrich; Raad Mohiaddin; Vivek Muthurangu; Saul Myerson; Andrew J Powell; Subha V Raman; Dudley J Pennell
Journal:  J Cardiovasc Magn Reson       Date:  2020-11-09       Impact factor: 5.364

10.  Normal values for aortic diameters in children and adolescents--assessment in vivo by contrast-enhanced CMR-angiography.

Authors:  Thomas Kaiser; Christian J Kellenberger; Manuela Albisetti; Eva Bergsträsser; Emanuela R Valsangiacomo Buechel
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-05       Impact factor: 5.364