Literature DB >> 12134979

Interatrial septum pacing avoids the adverse effect of interatrial delay in biventricular pacing: an echo-Doppler evaluation.

Maria Cristina Porciani1, Alessandra Sabini, Andrea Colella, Antonio Michelucci, Nicola Musilli, Paolo Pieragnoli, Luigi Padeletti.   

Abstract

AIMS: Biventricular pacing (BVP) can improve haemodynamics in patients with dilated cardiomyopathy (DCM) and left bundle branch block by reducing interventricular delay (IVD). Since in DCM interatrial delay (IAD) and IVD frequently coexist, the aim of this study was to test the hypothesis that IVD reduction associated with IAD produces an imbalance between the programmed right atrioventricular (AV) delay and the effective AV delay on the left, and that interatrial septum pacing (IASP) combined with BVP overcomes this adverse effect. METHODS AND
RESULTS: IAD, IVD, left and right mechanical atrioventricular delay (L-RMAVD) were measured by echo-Doppler in 29 patients with BVP: 17 patients (Group A) had the atrial lead in the right atrial appendage, 12 patients (Group B) who experienced paroxysmal atrial fibrillation had the atrial lead on the interatrial septum. In Group A, LMAVD was significantly shorter than RMAVD (172 +/- 24 vs 207 +/- 24 ms, P<0.002), IAD was significantly longer than IVD (52 +/- 24 vs 21 +/- 18 ms, P<0.0001). In Group B, no differences were observed between LMAVD and RMAVD (187 +/- 32 vs 185 +/- 28 ms, NS), and between IAD and IVD (11 +/- 12 vs 13 +/- 16 ms, NS).
CONCLUSIONS: IAD produces different left and right atrioventricular sequences in BVP. IASP combined with BVP, by resynchronizing both atria and ventricles, is able to avoid this adverse effect.

Entities:  

Mesh:

Year:  2002        PMID: 12134979     DOI: 10.1053/eupc.2002.0239

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  5 in total

1.  Implantation of lumenless pacing leads at the inter-atrial septum and right ventricular outflow tract with deflectable catheter-sheath.

Authors:  Rong Bai; Ruth Kam; Chi Keong Ching; Li Fern Hsu; Wee Siong Teo
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2008-12-24

2.  Current concepts in pacing 2010-2011: the right and wrong way to pace.

Authors:  Simon Modi; Andrew Krahn; Raymond Yee
Journal:  Curr Treat Options Cardiovasc Med       Date:  2011-10

3.  Interatrial conduction time and left atrial function in patients with left ventricular systolic dysfunction: effects of cardiac resynchronization therapy.

Authors:  Alan D Waggoner; Sujith Kalathiveetil; Karen E Spence; Víctor G Dávila-Román; Lisa de las Fuentes
Journal:  J Am Soc Echocardiogr       Date:  2009-04-02       Impact factor: 5.251

4.  P-wave dispersion and its relationship to aortic stiffness in patients with acute myocardial infarction after cardiac rehabilitation.

Authors:  Rezzan Deniz Acar; Mustafa Bulut; Sunay Ergün; Mahmut Yesin; Bilal Boztosun; Mustafa Akçakoyun
Journal:  ARYA Atheroscler       Date:  2014-07

5.  Impact of atrial septal pacing in left ventricular-only pacing in patients with a first-degree atrioventricular block: A case series.

Authors:  Yu Murata; Kohei Ishibashi; Kenichiro Yamagata; Chisato Izumi; Teruo Noguchi; Kengo Kusano
Journal:  HeartRhythm Case Rep       Date:  2021-12-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.