Literature DB >> 12132308

The frictional behavior of coated guiding archwires.

Pamela Husmann1, Christoph Bourauel, Michael Wessinger, Andreas Jäger.   

Abstract

BACKGROUND: The vast range of orthodontic wires made of different alloys makes it increasingly difficult for orthodontists to judge them. Coated orthodontic wires form a group of innovative guiding archwires.
MATERIAL AND METHODS: In the present in vitro study the frictional behavior of eight coated wires of different dimensions was investigated in archwire-guided canine retraction in the upper jaw. For this purpose five superelastic nickel titanium alloy wires (Titanol Low Force River Finish Gold and Gold 2: Forestadent, Pforzheim Germany; Titanol Superelastic tooth colored: Forestadent, Pforzheim Germany; BioForce Sentalloy Ionguard: GAC, Central Islip, NY, USA; NITI Imagination: GAC, Central Islip, NY, USA), two beta-titanium wires (TMA Low Friction Ionguard: Ormco, Glendora, CA, USA; TMA Low Friction Ionguard Purple: Ormco, Glendora, CA, USA), and one steel wire (Stainless steel Imagination: GAC, Central Islip, NY, USA) were selected. The coatings were made of Teflon or polyethylene, and by ion implantation. Three uncoated archwires (Rematitan Lite Dimple: Dentaurum, Pforzheim, German; Titanol Low Force River Finish: Forestadent, Pforzheim, Germany; BioForce Sentalloy: GAC, Central Islip, NY, USA) were used for comparison purposes. The force losses due to friction were measured using the Orthodontic Measurement and Simulation System (OMSS).
RESULTS: The results indicated that all coatings can reduce frictional losses compared with an uncoated reference wire by the same manufacturer. Measured frictional losses ranged from 48.3-6.1%, with the Teflon coatings reducing the frictional losses to less than 10% in some cases.
CONCLUSION: An unequivocal correlation between the surface roughness and frictional forces of the wires could not be verified by scanning electron microscopy.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12132308     DOI: 10.1007/s00056-002-0009-5

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  24 in total

1.  Comparative Evaluation of Frictional Properties, Load Deflection Rate and Surface Characteristics of Different Coloured TMA Archwires - An Invitro Study.

Authors:  Arul Pradeep Aloysius; Devaki Vijayalakshmi; Nagachandran Kandasamy Soundararajan; Vijaykumar Neelam Manohar; Nayeemullah Khan
Journal:  J Clin Diagn Res       Date:  2015-12-01

2.  Material testing of reconditioned orthodontic brackets.

Authors:  S Reimann; A Rewari; L Keilig; F Widu; A Jäger; C Bourauel
Journal:  J Orofac Orthop       Date:  2012-10-26       Impact factor: 1.938

3.  First order couples induced by nickel-titanium archwires featuring an electrochemically refined surface during simulated rotation of teeth.

Authors:  Leif Johannessen; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

4.  Friction behavior of self-ligating and conventional brackets with different ligature systems.

Authors:  Alexandra Szczupakowski; Susanne Reimann; Cornelius Dirk; Ludger Keilig; Anna Weber; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-05-24       Impact factor: 1.938

5.  Influence of thermal or chemical degradation on the frictional force of an experimental coated NiTi wire.

Authors:  Ana Maria Bezerra Bandeira; Marcia Pereira Alves dos Santos; Gino Pulitini; Carlos Nelson Elias; Marysilva Ferreira da Costa
Journal:  Angle Orthod       Date:  2011-02-07       Impact factor: 2.079

6.  Deflection test evaluation of different lots of the same nickel-titanium wire commercial brand.

Authors:  Murilo Gaby Neves; Fabrício Viana Pereira Lima; Júlio de Araújo Gurgel; Célia Regina Maio Pinzan-Vercelino; Fernanda Soares Rezende; Gustavo Antônio Martins Brandão
Journal:  Dental Press J Orthod       Date:  2016 Jan-Feb

7.  Surface characterization of nickel titanium orthodontic arch wires.

Authors:  Manu Krishnan; Saraswathy Seema; Brijesh Tiwari; Himanshu S Sharma; Sanjay Londhe; Vimal Arora
Journal:  Med J Armed Forces India       Date:  2014-04-03

8.  Evaluation of surface roughness of orthodontic wires by means of atomic force microscopy.

Authors:  Vincenzo D'Antò; Roberto Rongo; Gianluca Ametrano; Gianrico Spagnuolo; Paolo Manzo; Roberto Martina; Sergio Paduano; Rosa Valletta
Journal:  Angle Orthod       Date:  2012-02-15       Impact factor: 2.079

9.  Effect of coating on properties of esthetic orthodontic nickel-titanium wires.

Authors:  Masahiro Iijima; Takeshi Muguruma; William Brantley; Han-Cheol Choe; Susumu Nakagaki; Satish B Alapati; Itaru Mizoguchi
Journal:  Angle Orthod       Date:  2011-08-09       Impact factor: 2.079

10.  Effects of intraoral aging on surface properties of coated nickel-titanium archwires.

Authors:  Roberto Rongo; Gianluca Ametrano; Antonio Gloria; Gianrico Spagnuolo; Angela Galeotti; Sergio Paduano; Rosa Valletta; Vincenzo D'Antò
Journal:  Angle Orthod       Date:  2013-12-05       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.